Milla Jauhiainen Validation of Impedance Pneumography Measure- Ment for Assessment of Respiration in Cardiotho- Racic Surgery Patients
نویسندگان
چکیده
MILLA JAUHIAINEN: Validation of Impedance Pneumography Measurement for Assessment of Respiration in Cardiothoracic Surgery Patients Tampere University of Technology Master of Science Thesis, 50 pages May 2017 Master’s Degree Programme in Electrical Engineering Major: Biomedical Engineering Examiners: Associate Professor Jari Viik and Professor Jari Hyttinen Place of work: Biomedical Sciences and Engineering, Tampere University of Technology and Heart Center, Tampere University Hospital
منابع مشابه
Comparison of Acoustic Respiration Rate, Impedance Pneumography and Capnometry Monitors for Respiration Rate Accuracy and Apnea Detection during GI Endoscopy Anesthesia
Study Objective: To assess the accuracy of respiration rate measurements and the ability to detect apnea by capnometry, impedance pneumography and a new method, acoustic respiration rate monitoring, in anesthetized patients undergoing gastrointestinal endoscopy procedures. Design: Prospective observational study. Setting: Endoscopy procedures laboratory. Patients: 98 patients scheduled for uppe...
متن کاملDoes asthma-like increased breathing load influence impedance pneumography signal?
Asthma is a chronic disease characterized by recurrent attacks of breathlessness and wheezing. During an asthma attack, a bronchospasm occurs. In order to overcome increased resistance of airways forced breathing is necessary. It affects the intrapleural pressure, blood volume within the thoracic cavity and therefore it may affect also impedance pneumography signal. We tried to imitate asthma-l...
متن کاملImpedance pneumography: noise as signal in impedance cardiography.
Thoracic impedance is modulated by events within the respiratory cycle, which represents a source of "noise" in impedance cardiography. Respiration itself, however, is a physiological rhythm of interest to psychophysiologists. We report here methods and validation for deriving impedance pneumographic measures of respiration from impedance cardiography signals, based on standard tetrapolar band ...
متن کاملRespiration Rate Measurement Based on Impedance Pneumography
This document discusses the use of impedance pneumography as a technique to measure respiration rate. The generation of high-frequency ac current source is described, and the issues related to delay in modulated signal and finite transition times of carriers are addressed. The report also includes descriptions of potential implementations of a respiration rate measurement system using the ADS12...
متن کاملRespiratory Monitoring: Advantages of Inductive Plethysmography over Impedance Pneumography
Inductive plethysmography and impedance pneumography are two non-invasive technologies for measuring respiratory function. The following report describes the advantages of inductive plethysmography, which include greater accuracy and sensitivity; the ability to assess thoracoabdominal coordination; and the minimization of motion artifact. Together, these properties make inductive plethysmograph...