Heights in Morse-Taper Implants

نویسندگان

  • Ricardo Lillo
  • Carlos Parra
  • Ramón Fuentes
  • Eduardo Borie
  • Wilfried Engelke
  • Víctor Beltrán
چکیده

of abutments with two different diameters and transmucosal heights used for cementretained implant-supported prostheses in Morse-taper implants. Forty Morse-taper implants were divided into four groups with different abutment sizes for cement-retained prostheses in order to perform the compressive test. The groups were divided by abutment diameter and transmucosal height as follows: Group 1: 4.5 x 2.5 mm; Group 2: 4.5 x 3.5 mm; Group 3: 3.3 x 2.5 mm; and Group 4: 3.3 x 3.5 mm. An oblique compressive loading test was performed on each sample located in a platform at 30° using a universal testing machine with a load cell of 1,000 kgf and 0.5 mm/min speed until achieving the deformation of abutment’s neck. The compressive resistance and its mechanical behavior were recorded for each group and the data were analyzed using ANOVA, the Shapiro-Wilk and Scheffé tests. In addition, the detailed damage of all samples was recorded with a conventional camera linked to the endoscopic equipment. Significant differences were observed among the groups, except between Groups 2 and 3 (p>0.005). All the abutments showed permanent deformations in the upper region and at the transmucosal portion, but the threads of the screws were intact. Fractures were only identified in Groups 3 and 4. Stronger mechanical behavior and compressive resistance was observed in the abutments with 4.5 mm diameter and 2.5 mm transmucosal height. C o m p r e s s i v e R e s i s t a n c e o f A b u t m e n t s w i t h D i f f e r e n t D iameter s and Transmucosa l Heights in Morse-Taper Implants

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Morse taper dental implants and platform switching: The new paradigm in oral implantology

The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: "Bone loss and platform switching," "bone loss and implant-abutment joint," "bone reso...

متن کامل

Comparative evaluation of peri-implant tissues in patients wearing mandibular overdenture with different implant platforms

Background The poor hygiene of peri-implant tissues causes inflammation at tissue-implant interface, which may impair the rehabilitation success. The aim of this study was to evaluate the influence of external hexagon and Morse taper implants on peri-implant health in patients wearing mandibular overdentures for 1 year. Materials and Methods A total of 46 implants were evaluated, 28 external ...

متن کامل

Morse taper connection implants supporting "planned" maxillary and mandibular bar-retained overdentures: a 5-year prospective multicenter study.

OBJECTIVES In contrast to the excellent long-term outcomes described for implant-supported mandibular overdentures, less favorable long-term survival and success rates have been reported for maxillary implants supporting overdentures. The aim of this study was to evaluate the treatment outcome of "planned" bar-retained maxillary and mandibular overdentures supported by Morse taper connection im...

متن کامل

Prospective evaluation of 2,549 Morse taper connection implants: 1- to 6-year data.

BACKGROUND The aim of this study is to evaluate the implant survival, the implant-crown success, and the prosthetic complications of 2,549 Morse taper interference-fit connection implants. METHODS A total of 2,549 Morse taper connection implants were inserted in 893 patients from January 2003 until December 2008. At each annual recall, clinical, radiographic, and prosthetic parameters were as...

متن کامل

An in vitro investigation concerning the bacterial leakage at implants with internal hexagon and Morse taper implant-abutment connections.

PURPOSE To evaluate, in vitro, the leakage observed in internal hexagon and Morse taper implant-abutment connections. MATERIALS Ten specimens with internal hexagon and 10 with Cone Morse connection were used. The inner parts of 5 implants, per group, were inoculated with Pseudomonas aeruginosa (PS) suspension and 5 implants, per group, with Aggregatibacter actinomycetemcomitans (AA). The pene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015