The microdetermination of iodine in biological materials with special reference to the combustion of samples in the Parr oxygen bomb.
نویسندگان
چکیده
The most troublesome obstacle to the quantitative determination of the very minute quantities of iodine which are normally present in biological materials has been the destruction, without loss of iodine, of the relatively large amounts of organic matter present. The procedures which have been used to destroy the organic matter include fusion with alkali, combustion in a closed system, and digestion with sulfuric acid or hydrogen peroxide. Von Kolnitz and Remington (1) have critically reviewed all of these methods and point out serious objections to each. Leipert (2) developed a wet combustion method in which the organic matter is oxidized and the iodine is converted to iodine pentoxide by means of chromium trioxide in a sulfuric acid medium. Chromium trioxide usually contains iodine and is difficult to purify. Matthews, Curtis, and Brode (3) devised a method for preparing chromium trioxide of low iodine content. The chromium trioxide method is not directly applicable to biological materials of low iodine content such as food. For the analysis of liquid biological samples we have adapted and improved the acid permanganate method used by Riggs and Man (4) for determination of iodine in blood. Potassium permanganate is easily purified and is an excellent oxidizing agent. It serves also to indicate conveniently the amount of oxidizing agent required for complete oxidation of the organic matter, and in the distillation procedure the decoloration of the permanganate color is assurance of complete reduction of both the iodine and permanganate. However, the permanganate method is also not applicable directly to biological samples of low iodine content, such as food, which necessitate the oxidation of considerable organic matter. For such samples some type of closed combustion is usually employed. McClendon was the first to make closed combustions on biological materials in a bomb (5), but shortly discarded the bomb for a silica combustion tube (6). The latter method finally developed to the use of a platinum combustion tube with
منابع مشابه
Determining Total Mercury in Samples from the Persian Gulf and theCaspian Sea: Comparison of Dry Ash and Wet Extraction Mothods
Monitoring of mercury in environmental samples, with its proven toxicity on the food chain, requires sensitive and accurate analytical techniques. In this study, two methods for identification and quantification of total mercury in biological and sediment samples are compared: i) dry ash preparation and subsequent established procedures for Combustion Atomic Absorption Spectrometry, (AMA 254) ...
متن کاملNuclear Radiation and Thyroid Cancer; A Systematic Review
Background: The increasing prevalence of thyroid cancer among the survivors of atomic bomb attacks in Japan, nuclear fallout in the Marshall Islands, and Chernobyl nuclear power plant accident indicate a strong relationship between nuclear radiation and the occurrence of thyroid cancer. Materials and Methods: Systematic researches were conducted in the medical database of the American National ...
متن کاملDivergence times and morphological evolution of the subtribe Eritrichiinae (Boraginaceae-Rochelieae) with special reference to Lappula
The subtribe Eritrichiinae belongs to tribe Rochelieae (Borginaceae; Cynoglossoideae) which is composed of about 200 species in five genera including Eritrichium, Lappula, Hackelia, Lepechiniella, and Rochelia. The majority of the species are annual and grow in xeric habitats. The genus Lappula as an arid adapted and the second biggest genus...
متن کاملInvestigation of Auto Ignition Condition under Different Parameters
In this work, the potential of auto-ignition of heavy oil during in-situ combustion (ISC) process was studied. Kinetic studies were carried out using Thermo Gravimetric Analyzer (TGA), Differential Scanning Calorimetry (DSC) and Accelerating Rate Calorimetric (ARC) techniques. Effects of oxygen partial pressure, reservoir pressure and clay on auto ignition condition were investigated on a n...
متن کاملمروری بر انواع مختلف صفحه انژکتور متخلخل در سیستمهای پیشران فضایی؛ مطالعه موردی راندمان احتراق
Todaychr('39')s human life is undeniably dependent on satellites that have being sent to Earthchr('39')s orbit by space carriers. Delivery of any kind of cargo to space must be carried out by carriers, which are designed and optimized for the best energy consumption mood. One of the optimization steps in space carriers engine is to use porous materials in the engine injector plate. In this pap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of biological chemistry
دوره 161 شماره
صفحات -
تاریخ انتشار 1945