ThE POSTOPERATIVE RADIOLOGICAL EVALuATION OF ThE OxFORD MICROPLASTY uNICOMPARTMENTAL KNEE REPLACEMENT INSTRuMENTATION
نویسندگان
چکیده
Introduction. Recently, new model of Oxford mobile-bearing unicompartmental knee arthroplasty (UKA, Oxford Microplasty®, Zimmer Biomet, IN, USA) was launched to improve previous version (Oxford Phase 3, Biomet, IN, USA). Still, there are few reports demonstrating the results of this noble UKA prosthesis in the literature. Thus, the aim of this study is to report and assess the postoperative radiological outcomes of the Oxford Microplasty® instrument. Materials and methods. From March 2013 to October 2013, twenty-one patients (23 knees) underwent mobile UKA for medial compartment osteoarthritis using this noble instrument. Postoperative radiological outcomes were measured for operated lower limb alignment and implant position, and they were compared with those of 64 UKAs using the Oxford Phase 3 which had been performed from January 2010 to August 2012. Pre-and post-operative deformity of the knee in the coronal plane, the location of the mechanical axis with respect to the center of the tibial surface, positioning of the tibial and femoral components and varus and valgus alignment for the tibial and femoral components were evaluated. Results. In the Microplasty® patients, preoperative HKA angle was 172.8±2.5° and postoperative HKA angle increased to 177.7±2.8° (p<0.001). There were no significant differences in postoperative HKA angle between Oxford Phase 3 and Microplasty group (178.4° vs. 177.7°, p>0.05). There were no significant differences in postoperative limb alignment and component position between the Microplasty group and Oxford Phase 3 group except femoral component flexion (11.9±2.1° vs. 2.6±4.1°, p<0.001). In addition, there were not any outliers in measurements of the components in the Microplasty group. Conclusion. UKA using Oxford Microplasty® includes noble tools including femoral sizing spoon, G-clamp, longer IM rod, two-peg femoral component, and IM link system to help with ease of use, precision, efficiency, and reproducibility. Increased flexion of femoral component and increased total arc of femoral component will be more suitable especially for Asian patients who perform more flexion such as squatting and sitting on the floor in daily living activities.
منابع مشابه
Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience
Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...
متن کاملMedial Unicompartmental Osteoarthritis (MUO) of the Knee: Unicompartmental Knee Replacement (UKR) or Total Knee Replacement (TKR)
The aim of this review article is to analyze the clinical effectiveness of total knee replacement (TKR) compared to unicompartmental knee replacement (UKR) in patients with medial unicompartmental osteoarthritis (MUO) in terms of survival rates, revision rates and postoperative complications. The search engine was MedLine. The keywords used were: medial knee osteoarthritis. Three thousand and n...
متن کاملPre-operative clinical and radiological assessment of the patellofemoral joint in unicompartmental knee replacement and its influence on outcome.
Anterior knee pain and/or radiological evidence of degeneration of the patellofemoral joint are considered to be contraindications to unicompartmental knee replacement. The aim of this study was to determine whether this is the case. Between January 2000 and September 2003, in 100 knees (91 patients) in which Oxford unicompartmental knee replacements were undertaken for anteromedial osteoarthri...
متن کاملThe young patient and the medial unicompartmental knee replacement.
PURPOSE Younger patients with unicompartmental degenerative knee joint diseases present a therapeutic dilemma. The purpose of this study is to evaluate the long-term results of the Oxford phase III unicompartmental knee replacement through a minimally invasive approach in the young patient. METHODS We have studied a total of 51 patients (59 interventions) who underwent the Oxford Phase III Un...
متن کاملThe incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome.
Narrow, well-defined radiolucent lines commonly observed at the bone-implant interface of unicompartmental knee replacement tibial components have been referred to as physiological radiolucencies. These should be distinguished from pathological radiolucencies, which are poorly defined, wide and progressive, and associated with loosening and infection. We studied the incidence and clinical signi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -