Stability study of free radicals in 10 MeV electron beam irradiated quartz as an EPR dosimetry method

نویسندگان

  • Farhood Ziaie
  • Ahmad Mohammadzadeh
  • Mohammad Modarresi
  • F. Ziaie
چکیده

Many properties of a material, such as physical shape, crystalline or amorphous form, and particle size, may affect the quality of EPR response. The effects of mechanical treatment to a material such as grinding, crushing, and particle size on EPR signal were reported earlier [1, 9]. The EPR technique is a well known and well established method for dose measurement in several fields like radiation processing and retrospective dosimetry [8–13]. Many different materials such as alanine [5, 7, 12, 14], tooth enamel, and bone [2, 6, 12, 13, 15] have been extensively studied for their applications in radiation dosimetry using the EPR technique. It is also reported that the quartz materials have shown a good response to gamma rays in the dose ranges used for radiation processing and retrospective dosimetry, using the EPR techniques [8, 9]. These reasons plus the non-destructive nature of the radiation-induced defects when using the EPR technique, suggest that quartz could be a possible candidate for dose measurements in radiation processing and retrospective dosimetry. The main purpose of this study was to investigate the stability of the EPR response of quartz irradiated at different doses and dose rates with a 10 MeV electron beam. Stability study of free radicals in 10 MeV electron beam irradiated quartz as an EPR dosimetry method Farhood Ziaie, Ahmad Mohammadzadeh, Mohammad Modarresi

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities

Potassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities. Abstract With an increasing interest in using protons and light ions for radiation therapy there is a need for possibilities to simultaneously determine both absorbed dose (D) and linear energy transfer, LET, (LΔ). Potassium dithionate (K2S2O6) tablets were irradiated in...

متن کامل

Retrospective dosimetry using fingernail in nuclear industries: A review paper

Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...

متن کامل

Electron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel

Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...

متن کامل

Effects of water on fingernail electron paramagnetic resonance dosimetry

Electron paramagnetic resonance (EPR) is a promising biodosimetric method, and fingernails are sensitive biomaterials to ionizing radiation. Therefore, kinetic energy released per unit mass (kerma) can be estimated by measuring the level of free radicals within fingernails, using EPR. However, to date this dosimetry has been deficient and insufficiently accurate. In the sampling processes and m...

متن کامل

Dosimetry of Intense Particle Beams Using the Thermomechanical Behaviour of an Irradiated Aluminium Alloy

An hydrodynamic code coupled with a "PUFF-type" equation of state has been set up to investigate the thermomechanical behaviour of an aluminium alloy irradiated by a 1 MeV electron beam. The absorbed flux can reach 3500 J/cm2 with an exponential damping along 1 mm dep;th. A weaker flux .is produced with 1 MeV protons whose the stopping range is 10 pm for a 8000 J/g dose. Thermal stresses genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009