No superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups

نویسندگان

  • Kestutis Valancius
  • Kjeld Søballe
  • Poul T Nielsen
  • Mogens B Laursen
چکیده

BACKGROUND AND PURPOSE Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA- and porous-coated acetabular cups in a prospective randomized trial. METHODS This was an 8-year follow-up study of our previously published prospective randomized study to compare clinical outcomes, survival, periprosthetic bone mineral density, migration, and wear rates of HA- and porous-coated acetabular cups. Dual X-ray absorptiometry (DXA) and Ein Bild Roentgen Analyse (EBRA) measurements were used. 100 patients who underwent unilateral cementless total hip arthroplasty were randomized to either porous-coated cups or HA-coated cups. Patients were examined preoperatively and at 3, 6, and 9 months, and also 1, 3, and 8 years after surgery. 81 patients were available for 8-year follow-up, 40 with porous-coated cups and 41 with HA-coated cups. RESULTS Age, sex, bone mineral density, and clinical results (Harris hip score) were similar in the 2 groups. The survival, wear, and migration patterns of the cups were also similar in both groups. The results of periprosthetic bone mineral density scans in region of interest 2 was in favor of the porous-coated cups, but there were no differences between the 2 groups in all the remaining regions of interest. INTERPRETATION HA coating had no statistically significant effect on clinical results, survival, wear, or migration at the 8-year follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register.

We have compared the survival of two hydroxyapatite (HA)-coated cups, 1208 Atoll hemispheric and 2641 Tropic threaded, with cemented Charnley all-polyethylene cups (16 021) using the Cox regression model. The Tropic cup used in combination with an alumina ceramic femoral head, had good results, similar to those of the Charnley cup. When used in combination with a stainless-steel head, however, ...

متن کامل

Wear of metal-on-metal 'off-the-shelf' HA-coated/beaded hip bearings

Introduction Wear studies of metal-on-metal (MOM) bearings in hip simulators have historically involved ‘custom’ acetabular cups, i.e. having neither beaded layers nor biological coatings [1]. Such custom designs improve the accuracy of the gravimetric wear assessments. However, it is not always feasible to obtain custom cups for various reasons. Thus, another possibility would be to machine of...

متن کامل

Influence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.

Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...

متن کامل

Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-...

متن کامل

Hydroxyapatite coating of an acetabular prosthesis. Effect on stability.

We report the radiological and clinical outcome of a press-fit (SLF) acetabular component at two to three years in two groups of patients having primary total hip replacement. In 69 the implant was coated with hydroxyapatite (HA) and in 40 it was uncoated. The stability of the cup was assessed by measurement of proximal migration and change in the angle of inclination. The clinical results in t...