Contrasting effects of convective flow on catheter ablation lesion size: cryo versus radiofrequency energy.
نویسندگان
چکیده
BACKGROUND Cryoablation has now become an alternative to treat many cardiac arrhythmias, and may be the treatment of choice in some patient populations. We compared the effects of convective flow on large-tip cryo and radiofrequency (RF) lesions dimensions. METHODS Cryoablation and RF ablation were performed on porcine heart sections in a saline bath with varying directed flow rates. Cryoablation was performed for 4 minutes on 50 tissue pieces with tip temperature controlled at -80 degrees C. RF ablation was performed on 50 tissue pieces for 60 seconds at 60 degrees C tip temperature. The pieces were placed in culture media for 24 hours, and then sectioned, stained, and measured. RESULTS Cryoablation and RF lesion sizes varied significantly with flow such that higher flow rates produced smaller cryoablation lesions and larger RF lesions (mean cryoablation volumes: 854 +/- 402, 808 +/- 217, 781 +/- 217, 359 +/- 114, and 292 +/- 117 mm(3), and mean RF volumes: 211 +/- 35, 304 +/- 79, 439 +/- 125, 525 +/- 187, and 597 +/- 126 mm(3) for 0, 1, 2, 3, and 5 L/min flow rates, respectively, P < 0.0005). Trabeculated pieces had larger cryoablation lesions and smaller RF lesions than nontrabeculated ones at higher flow rate (P < 0.005). Cryoablation lesion volume increased as the time to reach -80 degrees C decreased (r(2)= 0.72). CONCLUSION In contrast to RF ablation, cryoablation lesion size is smaller at high flow rates, and larger at low flow rates due to the warming effects of local convective flow. The effects of high flow are reduced in areas of trabeculation, and the time to reach -80 degrees C predicts cryoablation lesion size.
منابع مشابه
Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling.
BACKGROUND It is important to increase lesion size to improve the success rate for radiofrequency ablation of ischemic ventricular tachycardia. This study of radiofrequency ablation, with adjustment of power to approach a preset target temperature, ie, temperature-controlled ablation, explores the effect of catheter-tip length, ablation site, and convective cooling on lesion dimensions. METHO...
متن کاملConvective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation.
BACKGROUND Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. METHODS Porcine hearts were sectioned int...
متن کاملLESION SIZE ESTIMATOR FOR CARDIAC RADIOFREQUENCY ABLATION by YU-CHI LAI UNIVERSITY OF WISCONSIN-MADISON DEPT. OF ELECTRICAL AND COMPUTER ENGINEERING
This work outlines a process for finite element (FE) modeling implementations of temperaturecontrolled radiofrequency (RF) ablation (TCRFA) with an automated temperature controller to investigate effects of changes in control temperature and contact conditions on the formation of lesions. The conditions investigated include ablation location, dimension of the myocardium, blood–electrode and blo...
متن کاملEpicardial Catheter Ablation Using High-Intensity Ultrasound: Validation in a Swine Model.
BACKGROUND Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, ...
متن کاملA balloon occlusion technique to overcome the convective warming effect of coronary sinus blood flow on cryoablation
Introduction Since its first human application in 1998, transcatheter cryoablation has emerged as a viable alternative to radiofrequency ablation. Its enhanced safety profile, including an obligatory phase of reversible tissue inhibition prior to permanent cellular damage, has rendered cryoablation an attractive treatment option for perinodal and peri-Hissian substrates. Several factors may inf...