Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty.

نویسندگان

  • J Chouteau
  • J-L Lerat
  • R Testa
  • B Moyen
  • M-H Fessy
  • S A Banks
چکیده

INTRODUCTION Total knee prostheses with a mobile-bearing insert were developed to provide nonconstrained joint range of motion while reducing friction forces. The purpose of this study was, based on weightbearing X-rays, to evaluate the mobility of the polyethylene tibial insert in relation to the femoral and tibial components. We studied the results of a cementless total knee arthroplasty (TKA) retaining the posterior cruciate ligament (PCL), with a mobile-bearing platform in rotation and anteroposterior translation (Innex Anterior-Posterior Glide, Zimmer) with a mean 23-month follow-up duration after surgery. HYPOTHESIS Both anterior-posterior tibiofemoral translation and intraprosthetic axial rotation occur between the mobile polyethylene insert and the tibial endplate. MATERIAL AND METHOD In a series of 51 primary TKA, the three-dimensional (3D) kinematics of the femoral, tibial, and mobile insert components were determined using a computerized matching system between the prosthetic 3D models and the radiographic images of the implants on three lateral follow-up weightbearing knee X-rays: films were taken in full extension, at 45 degrees flexion, and at maximum flexion. RESULTS There was a statistically significant increase in the internal rotation of the mobile tray with flexion, (up to a mean -3+/-3 degrees between the femoral box and the mobile tray [p<0.0001] and up to a mean -5+/-7 degrees between the tibial tray and the mobile tray [p<0.0001]). The mobile tray did not translate in relation to the tibial endplate from extension to 45 degrees flexion (0+/-2 mm [range: -5 to 6 mm]). However, from 45 degrees to maximum flexion, a statistically significant mean 1+/-2 mm (range: -2 to 9 mm) of anterior translation (p<0.0001) was found. DISCUSSION The extent of insert mobility varies from one study to another. Some have reported relatively limited mobility stemming from a superior surface that is not highly congruent, (thus allowing anterior-posterior and mediolateral translation through gliding of the femur in contact with the insert). Other studies have reported mobile-bearing tray mobility in relation to the tibial endplate and minimal rotation at the femoral component level. In this series of PCL retaining TKA with a mobile-bearing platform, the mobile-bearing platform showed a progressive increase in internal rotation during flexion. Most of this rotational mobility occurred between the mobile platform and the tibial endplate, confirming our hypothesis. However, with flexion, the femoral component increased its mobility relatively to the platform. During flexion, an anterior-posterior translation occurred between the femoral implant and the tibial insert, and between the tibial insert and the tibial endplate, but the direction of the mobile tibial insert translation remained unpredictable with this nonconstrained implant design used. LEVEL OF EVIDENCE Level IV. Prospective non-controlled therapeutic study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mobile - bearing kinematics in PCL - retaining total knee arthroplasty . A study of 51 cases

Mobile-bearing kinematics in PCL-retaining total knee arthroplasty. A study of 51 cases Julien Chouteau1,2,3, Jean-Luc Lerat1, Rodlph Testa1, Bernard Moyen1,2, Michel-Henry Fessy1, Scott A. Banks3 1Department of Orthopaedics, trauma and sport medicine, Lyon-Sud Hospital, Pierre-Bénite, France; 2Université Lyon 1, F-69003 ; Institut National de Recherche sur les Transports et leur Sécurité, Bron...

متن کامل

Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint

BACKGROUND The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the...

متن کامل

Similar outcome after retention or sacrifice of the posterior cruciate ligament in total knee arthroplasty

The purpose of this study was to answer 2 questions: Does the posterior cruciate ligament (PCL) produce femoral rollback in a single-design, cruciate-sparing total knee arthroplasty (TKA)? Does the PCL prevent posterior tibial displacement when it is retained after a single-design, cruciate-sparing TKA? Knee kinematics and limits of motion were measured with the knees in the following states: (...

متن کامل

In vivo determination of total knee arthroplasty kinematics: a multicenter analysis of an asymmetrical posterior cruciate retaining total knee arthroplasty.

The objective of this study was to determine if consistent posterior femoral rollback of an asymmetrical posterior cruciate retaining (PCR) total knee arthroplasty was mostly influenced by the implant design, surgical technique, or presence of a well-functioning posterior cruciate ligament (PCL). Three-dimensional femorotibial kinematics was determined for 80 subjects implanted by 3 surgeons, a...

متن کامل

A kinematic comparison of fixed- and mobile-bearing knee replacements.

Mobile-bearing posterior-stabilised knee replacements have been developed as an alternative to the standard fixed- and mobile-bearing designs. However, little is known about the in vivo kinematics of this new group of implants. We investigated 31 patients who had undergone a total knee replacement with a similar prosthetic design but with three different options: fixed-bearing posterior cruciat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 95 4  شماره 

صفحات  -

تاریخ انتشار 2009