CdZnTe Background Measurement at Balloon Altitudes with an Active BGO Shield
نویسنده
چکیده
We report results of an experiment conducted in May 1997 to measure CdZnTe background and background reduction schemes in space flight conditions similar to those of proposed hard X-ray astrophysics missions. A 1 cm CdZnTe detector was placed adjacent to a thick BGO anticoincidence shield and flown piggybacked onto the EXITE2 scientific balloon payload. The planar shield was designed to veto background counts produced by local gamma-ray production in passive material and neutron interactions in the detector. The CdZnTe and BGO were partially surrounded by a Pb-Sn-Cu shield to approximate the grammage of an X-ray collimator, although the field of view was still ∼ 2π sr. At an altitude of 127000 feet we find a reduction in background by a factor of 6 at 100 keV. The non-vetoed background is 9× 10 cts cm s keV at 100 keV, about a factor of 2 higher than that of the collimated (4.5 FWHM) EXITE2 phoswich detector. We compare our recorded spectrum with that expected from simulations using GEANT and find agreement within a factor of 2 between 30 and 300 keV. We also compare our results with those of previous experiments using passive lead and active NaI shields, and discuss possible active shielding schemes in future astronomy missions employing large arrays of CdZnTe detectors.
منابع مشابه
CdZnTe Gamma Ray Spectrometer for Orbital Gamma Ray Spectroscopy
We present the design and analysis of a new gamma ray spectrometer for planetary science that uses an array of CdZnTe detectors to achieve the detection efficiency needed for orbital measurements. The use of CdZnTe will provide significantly improved pulse height resolution relative to scintillation-based detectors, with commensurate improvement in the accuracy of elemental abundances determine...
متن کاملA GRB Detection System using the BGO-Shield of the INTEGRAL-Spectrometer SPI
The anticoincidence shield (ACS) of the INTEGRAL-spectrometer SPI consists of 512 kg of BGO crystals. This massive scintillator allows the measurement of gamma-ray bursts (GRBs) with a very high sensitivity. Estimations have shown that with the ACS some hundred gamma-ray bursts per year on the 5 σ level can be detected, having an equivalent sensitivity to BATSE. The GRB detection will be part o...
متن کاملDesign and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy
We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...
متن کاملThe CERN-EU high-energy reference field (CERF) facility for dosimetry at commercial flight altitudes and in space.
A reference facility for the calibration and intercomparison of active and passive detectors in broad neutron fields has been available at CERN since 1992. A positively charged hadron beam (a mixture of protons and pions) with momentum of 120 GeV/c hits a copper target, 50 cm thick and 7 cm in diameter. The secondary particles produced in the interaction traverse a shield, at 90 degrees with re...
متن کاملBalloon Flight Background Measurement with Actively-Shielded Planar and Imaging CZT Detectors
We present results from the flight of two prototype CZT detectors on a scientific balloon payload in September 2000. The first detector, referred to as “CZT1,” consisted of a 10 mm × 10 mm × 2 mm CZT crystal with a single gold planar electrode readout. This detector was shielded by a combination of a passive collimator in the front, giving a 40 degree field of view and surrounded by plastic sci...
متن کامل