Surgical Treatment of Distal Radius Fractures with a Volar Locked Plate: Correlation of Clinical and Radiographic Results.

نویسندگان

  • Claudio Roberto Martins Xavier
  • Danilo Canesin Dal Molin
  • Rafael Mota Marins Dos Santos
  • Roberto Della Torre Dos Santos
  • Julio Cezar Ferreira Neto
چکیده

OBJECTIVES To analyze and correlate the clinical and radiographic results from patients with distal radius fractures who underwent surgical treatment with a fixed-angle volar locked plate. METHODS Sixty-four patients with distal radius fractures were evaluated. They all underwent surgical treatment with a volar locked plate for the distal radius, with a minimum of six months of postoperative follow-up. They underwent a physical examination that measured range of motion and grip strength, answered the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and underwent radiographic examination. RESULTS In the physical examination on the patients, all the range-of-motion measurements were reduced. Grip strength measured in kgf was on average 85.8% of the strength on the unaffected side. The mean DASH score was 15.99. A significant relationship was found between lower DASH scores and losses of extension and grip strength. On the radiographs, the mean values in relation to the unfractured side were 84.0% for radial inclination, 85.4% for radial length and 86.8% for volar deviation of the radius. Loss of radial length was correlated with losses of extension and grip strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Statistical Analysis on Functional and Radiographic Results after Use of Locked Volar Plate for Fractures of the Distal Radius

OBJECTIVES To evaluate the functional results from using a fixed-angle locked volar plate for treating fractures of the distal extremity of the radius, using the DASH (disorders of the arm, shoulder and hand) questionnaire and its radiographic correlation with the Lidström classification. METHODS Thirty patients with unstable fractures of the distal extremity of the radius were evaluated afte...

متن کامل

Economic Analysis of the Cost of Implants Used for Treatment of Distal Radius Fractures

Background: There are a number of different implant choices for surgical treatment of distal radius fractures, oftendetermined by surgeon preference or availability. Although no one volar plate demonstrates superior outcomes, thereare significant cost differences absorbed by hospitals and surgical centers. This purpose of this study is to characterizethe economic implications of implant selecti...

متن کامل

Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial.

INTRODUCTION Fractures of the distal radius are very common and mainly occur in the elderly. There has been an increasing use of locked volar plate fixations which report satisfactory results. However, some authors advocate the use of nail fixation. HYPOTHESIS The aim of this study is to compare dorsal nail plate versus locked volar plate fixation in the treatment of distal radius fractures w...

متن کامل

Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.

PURPOSE To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. METHODS A simulated, unstable, extra- articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator [Mirza Cross Pin Fixator (CPX)...

متن کامل

Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year

BACKGROUND AND PURPOSE Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation. PATIENTS AND METHODS 63 patients under 70 years of age, with an unstable e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de ortopedia

دوره 46 5  شماره 

صفحات  -

تاریخ انتشار 2011