Three Echo Dixon Water-Fat Separation for Cardiac Black Blood Turbo Spin Echo Imaging

نویسندگان

  • P. Koken
  • H. Eggers
  • T. Schaeffter
  • P. Börnert
چکیده

Introduction Turbo spin echo (TSE) sequences with black blood preparation pulses are an important component of cardiac MRI. It is commonly used for tissue characterization and anatomical assessment of the myocardium, e.g. for edema imaging aiming at the differentiation of acute from chronic myocardial infarction. TSE benefits from high SNR and the availability of good T1 or T2 weighting. So far it is often combined with an additional fat suppression prepulse to improve contrast. But recent studies showed, that the fat in and around the heart could be of diagnostic value [1,2]. For example, the amount of fat deposition in the myocardium can be used to characterize chronic myocardial infarction. In cases of suspected cardiac masses, the separation of water and fat components is essential for a confident diagnosis. Recently, the combination of multi-echo Dixon imaging with a fly-back gradient echo sequence was proposed for water/fat separated imaging of the heart [1,2]. Either a three-echo-train with inand outphase echoes [1] or a four-echo-train [2] was used. In this feasibility study, we propose the combination of black blood TSE with a three echo GRASE-like readout and an iterative water/fat separation reconstruction. Acquiring data at both polarities of the readout gradient increases the sampling efficiency. Appropriate signal correction in combination with accelerated parallel imaging allows fast water/fat resolved cardiac imaging. The pulse sequence is similar to the one proposed in [3], but without restrictions to the inter echo time. Methods Data were acquired in healthy volunteers on a 1.5T clinical scanner (Achieva, Philips Healthcare, Best, The Netherlands) using a 5-element cardiac coil. A modified multi-slice black blood TSE sequence was used as shown in Figure 1. Data were acquired ECG-triggered at a delay of 650 ms after the RR-wave. The black blood preparation consisted of a non-selective 180° pulse followed by a sliceselective 180° pulse. After the blood T1-specific and heart rate depended delay time, TSE data collection was started. In the TSE, phase encoding was applied only once after each 180° refocusing pulse, such that the alternating readout gradient encoded the same k-space line three times. Beside the central Spinecho, a gradient echo was acquired at ΔTE = ±1.8 ms, respectively. 16 different k-space lines were encoded per cardiac cycle in a linear order, preceded by 4 startup echoes, resulting in an effective echo time of TE = 130ms. A short axis view was depicted with an in-plane FOV of 350 × 318 mm and a voxel size of 1.15 × 1.15 mm. 10 slices were acquired with a slice thickness of 10 mm, each in one breath-hold of approx. 16 s. A SENSE factor of 2 was used; therefore, coil sensitivity maps were acquired in a preceding reference scan. During reconstruction, first, the inconsistencies between the odd and the even echoes were corrected using reference data measured just before the scan [4]. SENSE unfolding is performed resulting in one stack of ten slices for each of the three echo times. With this already reduced amount of data, an image-based iterative water/fat separation was performed using a region-growing algorithm for local B0 inhomogeneity estimation, similar to the method described by Yu et al. [5]. Results and Discussion Figure 2 shows the final water and fat reconstruction of two selected slices of a selected volunteer in a short axis view. Very good image quality, blood signal suppression inside the ventricle and water/fat separation was achieved. The iterative least-squares decomposition method is very flexible concerning the echo spacing. It has been shown that proper specification of the ΔTE is advantageous in terms of SNR [6], but in principle any choice of ΔTE is possible. Therefore, in any existing TSE cardiac protocol, the so far applied fat suppression could be exchanged easily with the presented method of acquiring three echoes instead. Beside the more stable fat suppression in the presence of B0 inhomogeneity, the additional information of the distribution of water and fat could be of great diagnostic benefit. In addition, the prolonged overall signal sampling time results in an improved SNR in the water image. This is especially true, when compared to an improper fat suppression, which does not only remove signal from the fat species, but in some image regions also from water tissue. Of course, the main disadvantage of all multi-echo Dixon water/fat separation imaging methods remains, i.e. the scan time is prolonged compared to a one echo imaging method with spectral selective excitation or spectral selective suppression. Here, the time between two refocusing pulses has to be increased to be able to sample three echoes instead of one. To use the same effective echo time and to prevent image blurring caused by a prolonged echo train, the number of k-space lines encoded during one cardiac cycle has to be reduced compared to the one echo scan. This will increase the number of needed cardiac cycles, and hence the overall scan time. But so far, this three-echo bipolar GRASE-like readout is the most efficient way to acquire data at three different echo times for TSE water/fat separated cardiac imaging. Conclusion The proposed modification of an established black blood TSE sequence is capable of adding very useful diagnostic information at the cost of a slightly prolonged overall scan time. Even when only the water image is of interest, the method can be superior to a one echo method with prepulse fat suppression in terms of increased SNR and better fat suppression in the presence of B0 inhomogeneity. Further studies are needed to show the applicability in the clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Water-fat separation with parallel imaging based on BLADE.

Uniform suppression of fat signal is desired in clinical applications. Based on phase differences introduced by different chemical shift frequencies, Dixon method and its variations are used as alternatives of fat saturation methods, which are sensitive to B0 inhomogeneities. Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) separates water and fa...

متن کامل

Fast spin-echo triple-echo dixon (fTED) technique for efficient T2-weighted water and fat imaging.

Previously published fast spin-echo (FSE) implementations of a Dixon method for water and fat separation all require multiple scans and thus a relatively long scan time. Further, the minimum echo spacing (esp), a time critical for FSE image quality and scan efficiency, often needs to be increased in order to bring about the required phase shift between the water and fat signals. This work propo...

متن کامل

Fast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm.

Three-point Dixon techniques achieve good lipid-water separation by estimating the phase due to field inhomogeneities. Recently it was demonstrated that the combination of an iterative algorithm (iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL)) with a fast spin-echo (FSE) three-point Dixon method yielded robust lipid-water decomposition. As an a...

متن کامل

Fast three-point Dixon MR imaging of the retrobulbar space with low-resolution images for phase correction: comparison with fast spin-echo inversion recovery imaging.

A new phase-correction algorithm for three-point Dixon (3PD) MR imaging allows on-line image reconstruction of three images per section: pure water, pure fat, and water plus fat. When combined with fast spin-echo acquisition, the sequence is suitable for routine MR imaging of the retrobulbar space. The 3PD pure water images have double the image signal-to-noise ratio of fast spin-echo inversion...

متن کامل

Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

This work describes a new approach to multipoint Dixon fat-water separation that is amenable to pulse sequences that require short echo time (TE) increments, such as steady-state free precession (SSFP) and fast spin-echo (FSE) imaging. Using an iterative linear least-squares method that decomposes water and fat images from source images acquired at short TE increments, images with a high signal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009