Tensile strength of modified 4-strand cruciate technique for transversely or obliquely lacerated tendons.
نویسندگان
چکیده
PURPOSES To assess the tensile strength of the modified 4-strand cruciate technique for obliquely lacerated tendons, and to compare the findings with the strength of transversely lacerated tendons repaired at various grasping depths. METHODS 60 porcine front foot tendons were evenly divided into 4 groups. In groups 1 to 3, tendons were transversely lacerated and repaired with grasping points at both ends away from the laceration by 5 mm, 10 mm, and 15 mm respectively. In group 4, tendons were obliquely lacerated and repaired with a grasping point 5 mm away from the laceration on one end and 15 mm on the other. All tendons were repaired with a modified 4-strand core suture and continuous epitendinous suture, and then tested to failure in a tensile machine. RESULTS The tensile strength in group 1 was significantly lower than that in the other 3 groups (p<0.005). The tensile strength in group 4 was not significantly different from groups 2 and 3. CONCLUSION The tensile strength of modified 4-strand cruciate repair configuration is not weakened in obliquely lacerated tendons; the grasping point at one end of the tendon being 15 mm away from laceration provides sufficient strength to compensate for the relatively weak 5-mm end. So long as one grasping point is away from the laceration site by 10 mm, the ultimate tensile strength of the transversely lacerated tendons appears acceptable. The modified 4-strand cruciate repair is safe to use for repairing obliquely lacerated tendons.
منابع مشابه
A biomechanical study of pediatric flexor profundus tendon repair
OBJECTIVES To investigate the tensile strength of repaired flexor profundus tendons in young lambs, which would be equivalent to repairs in children older than 2 years of age. METHODS A comparative in-vitro experimental study conducted at King Saud University, Riyadh, Kingdom of Saudi Arabia from October 2014 to December 2015. We utilized 30 flexor profundus tendons of young lambs with a widt...
متن کاملDevelopment of biodegradable polycaprolactone film as an internal fixation material to enhance tendon repair: an in vitro study
BACKGROUND Current tendon repair techniques do not provide sufficient tensile strength at the repair site, and thus early active motion rehabilitation after tendon repair is discouraged. To enhance the post-operative tensile strength, we proposed and tested an internal fixation technique using a polycaprolactone (PCL) biofilm. PCL was chosen for its good biocompatibility, excellent mechanical s...
متن کاملEffects of braiding on tensile properties of four-strand human hamstring tendon grafts.
BACKGROUND Anterior cruciate ligament reconstruction is commonly performed with autogenous hamstring tendon grafts. PURPOSE To ascertain the effects of braiding on ultimate tensile strength and stiffness of hamstring tendon graft. STUDY DESIGN Controlled laboratory study. METHODS Sixteen fresh-frozen semitendinosus and gracilis tendons were harvested from eight matched (right and left) hu...
متن کاملTwisting and braiding reduces the tensile strength and stiffness of human hamstring tendon grafts used for anterior cruciate ligament reconstruction.
BACKGROUND Twisting and braiding of four-strand hamstring tendon grafts used for anterior cruciate ligament reconstruction has been proposed, but not proven, as a method of improving tensile properties. HYPOTHESIS Twisting and braiding four-strand human hamstring tendon grafts will have no significant effect on initial graft strength or stiffness. STUDY DESIGN Paired in vitro biomechanical ...
متن کاملA biomechanical analysis of multistrand repairs with the Silfverskiold peripheral cross-stitch.
We compared the bulking and tensile strength of the Pennington modified Kessler, Cruciate and the Savage repairs in an ex vivo model. A total of 60 porcine tendons were randomised to three groups, half repaired using a core suture alone and the remainder employing a core and peripheral technique. The tendons were distracted to failure. The force required to produce a 3 mm gap, the ultimate stre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic surgery
دوره 15 1 شماره
صفحات -
تاریخ انتشار 2007