Clinical evaluation of small-diameter ITI implants: a prospective study.

نویسندگان

  • Barbara Zinsli
  • Tanja Sägesser
  • Ernoe Mericske
  • Regina Mericske-Stern
چکیده

PURPOSE Dental implants with a reduced diameter are designed for specific clinical situations, such as placement of implants where bone width is narrow or between adjacent teeth that have only a narrow space between them. They are particularly useful when replacing small teeth such as lateral maxillary and mandibular incisors. The aim of the present study was the clinical evaluation of 2-part ITI implants (full-body screws with a 3.3-mm diameter). MATERIALS AND METHODS One hundred forty-nine partially or completely edentulous patients received a total of 298 2-part ITI implants over a 10-year period. After a standard healing period (3 to 6 months), the implants were restored with fixed restorations such as single crowns or fixed partial or complete prostheses or overdentures. Complete prosthesis or overdenture in the edentulous jaw was the predominant type of restoration. All patients followed a strict maintenance program, with regular recalls at least once a year. The survival rate of the implants was analyzed, and prosthetic complications were assessed. RESULTS Three implants were lost during the healing phase on account of peri-implant infection. Two implant body fractures with an osseous length of 8 mm were observed (one after 2 years of observation, the other after 6 years). Four implants exhibited transient peri-implant inflammation that was treated successfully by interceptive therapy. The cumulative 5-year survival rate of the implants was 98.7% (96.6% after 6 years). Prosthetic complications were mostly limited to loose occlusal screws and sore spots caused by the denture base. DISCUSSION Within the limited observation period, failures of small-diameter implants were infrequent. Prosthetic complications were not dependent on the use of small-diameter implants. CONCLUSION The use of 3.3-mm ITI implants appears to be predictable if clinical guidelines are followed and appropriate prosthetic restorations are provided. However, fatigue fracture may occur after a long period of function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study

PURPOSE: Dental implants with a reduced diameter are designed for specific clinical situations, such as placement of implants where bone width is narrow or between adjacent teeth that have only a narrow space between them. They are particularly useful when replacing small teeth such as lateral maxillary and mandibular incisors. The aim of the present study was the clinical evaluation of 2-part ...

متن کامل

ارزیابی گذشته نگر یک تا شش سال کاربرد ایمپلنت های دندانی ITI با استفاده از معیارهای کلینیکی و رادیوگرافیک

In the past two decades, replacement of the missing teeth with implant borne prosthesis has become a treatment modality, accepted by the scientific community for fully and partially edentulous patients. The aim of the present study is to evaluate retrospectively, 502 ITI dental implants application, in partial and complete edentulous patients, treated in two private centers, based on clinical a...

متن کامل

Two-stage IMZ implants and ITI implants inserted in a single-stage procedure. A prospective comparative study.

The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V-VI) participated in this study. After randomisation, 20 patients received two IMZ implants inserted in a single-sta...

متن کامل

Mandibular overdentures supported by two Brånemark, IMZ or ITI implants: a 5-year prospective study.

OBJECTIVES The aim of this prospective comparative study was to evaluate the survival rate and the condition of the peri-implant tissues of the IMZ implant system (two-stage cylindertype), the Brånemark implant system (two-stage screwtype) and the ITI implant system (one-stage screwtype) supporting a mandibular overdenture during a 5-year follow-up period. MATERIAL AND METHODS Three groups of...

متن کامل

Evaluation of Stability Changes in Tapered and Parallel Wall Implants: A Human Clinical Trial

OBJECTIVE To determine the pattern of stability changes as a reflection of early healing around single-stage roughened-surface implants in humans utilizing resonance frequency analysis (RFA). MATERIALS AND METHODS Hundred twenty-five patients who demanded dental implants were treated with two different implant (Nobel Biocare Replace™ and Strumman™ ITI) systems. Bone type was classified into f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2004