Multi-vendor reliability of arterial spin labeling perfusion MRI using a near-identical sequence: Implications for multi-center studies

نویسندگان

  • Henri J. M. M. Mutsaerts
  • Matthias J. P. van Osch
  • Fernando O. Zelaya
  • Danny J. J. Wang
  • Wibeke Nordhøy
  • Yi Wang
  • Stephen Wastling
  • María A. Fernández-Seara
  • Esben Thade Petersen
  • Francesca Benedetta Pizzini
  • Sameeha Fallatah
  • Jeroen Hendrikse
  • Oliver Geier
  • Matthias Günther
  • Xavier Golay
  • Aart J. Nederveen
  • Atle Bjørnerud
  • Inge R. Groote
چکیده

INTRODUCTION A main obstacle that impedes standardized clinical and research applications of arterial spin labeling (ASL), is the substantial differences between the commercial implementations of ASL from major MRI vendors. In this study, we compare a single identical 2D gradient-echo EPI pseudo-continuous ASL (PCASL) sequence implemented on 3T scanners from three vendors (General Electric Healthcare, Philips Healthcare and Siemens Healthcare) within the same center and with the same subjects. MATERIAL AND METHODS Fourteen healthy volunteers (50% male, age 26.4±4.7years) were scanned twice on each scanner in an interleaved manner within 3h. Because of differences in gradient and coil specifications, two separate studies were performed with slightly different sequence parameters, with one scanner used across both studies for comparison. Reproducibility was evaluated by means of quantitative cerebral blood flow (CBF) agreement and inter-session variation, both on a region-of-interest (ROI) and voxel level. In addition, a qualitative similarity comparison of the CBF maps was performed by three experienced neuro-radiologists. RESULTS There were no CBF differences between vendors in study 1 (p>0.1), but there were CBF differences of 2-19% between vendors in study 2 (p<0.001 in most gray matter ROIs) and 10-22% difference in CBF values obtained with the same vendor between studies (p<0.001 in most gray matter ROIs). The inter-vendor inter-session variation was not significantly larger than the intra-vendor variation in all (p>0.1) but one of the ROIs (p<0.001). CONCLUSION This study demonstrates the possibility to acquire comparable cerebral CBF maps on scanners of different vendors. Small differences in sequence parameters can have a larger effect on the reproducibility of ASL than hardware or software differences between vendors. These results suggest that researchers should strive to employ identical labeling and readout strategies in multi-center ASL studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...

متن کامل

Multiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity

A novel sequence has been introduced that combines multiband imaging with a multi-echo acquisition for simultaneous high spatial resolution pseudo-continuous arterial spin labeling (ASL) and blood-oxygenation-level dependent (BOLD) echo-planar imaging (MBME ASL/BOLD). Resting-state connectivity in healthy adult subjects was assessed using this sequence. Four echoes were acquired with a multiban...

متن کامل

Patterns of postictal cerebral perfusion in idiopathic generalized epilepsy: a multi-delay multi-parametric arterial spin labelling perfusion MRI study

The cerebral haemodynamic status of idiopathic generalized epilepsy (IGE) is a very complicated process. Little attention has been paid to cerebral blood flow (CBF) alterations in IGE detected by arterial spin labelling (ASL) perfusion magnetic resonance imaging (MRI). However, the selection of an optimal delay time is difficult for single-delay ASL. Multi-delay multi-parametric ASL perfusion M...

متن کامل

Precision and Accuracy of Arterial Spin Labeling Perfusion MRI in the Pediatric Population

Introduction Arterial Spin Labeling (ASL) provides a noninvasive means for measuring quantitative cerebral blood flow (CBF) without the use of exogenous contrast agents, and is particularly appealing for pediatric populations (1). In neurodevelopmental studies, quantitative CBF can serve as an important marker of cognitive development in normal children as well as aberrant changes in brain func...

متن کامل

Clinical assessment of brain perfusion in newborn infants with arterial spin labeling perfusion MRI

INTRODUCTION. Many approaches have been applied to evaluate brain perfusion in neonates: brain ultrasound, near-infrared spectroscopy, and positron emission tomography (PET). However perfusion weighted imaging (PWI) MRI has been shown to enable in vivo direct measurements of brain perfusion in different brain regions. Recent advances have lead to the development of non-contrast agent based Arte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 113  شماره 

صفحات  -

تاریخ انتشار 2015