The pediatric stroke outcome measure: a validation and reliability study.

نویسندگان

  • Lisa Kitchen
  • Robyn Westmacott
  • Sharon Friefeld
  • Daune MacGregor
  • Rosalind Curtis
  • Anita Allen
  • Ivanna Yau
  • Rand Askalan
  • Mahendranath Moharir
  • Trish Domi
  • Gabrielle deVeber
چکیده

BACKGROUND AND PURPOSE The Pediatric Stroke Outcome Measure (PSOM) is an objective, disease-specific outcome measure containing 115 test items suitable for newborn to adult ages. The PSOM measures neurological deficit and function across 5 subscales: right sensorimotor, left sensorimotor, language production, language comprehension, and cognitive/behavior yielding a final 10-point deficit score. The goal of this study was to examine PSOM construct validity in measuring neurological outcome in pediatric stroke survivors and interrater reliability (IRR) for both prospective and retrospective scoring. METHODS For construct validity, PSOM subscale scores were correlated with scores on standardized neuropsychological measures matched by functional domain. We assessed IRR by comparing same-day "live" PSOM scores from 2 independent raters in 10 children (prospective IRR) and by comparing PSOM scores estimated from medical dictations across 5 raters in another 10 children (retrospective IRR). RESULTS We analyzed PSOM scores from 203 children with ischemic stroke. PSOM subscales show good construct validity (ρ=0.2-0.4; P<0.05). PSOM subscale scores of normal/abnormal demonstrate strong agreement for domain-matched neuropsychology scores (alternative chance-corrected statistic=0.4-0.8). IRR was excellent with the 2 prospective raters' scores in almost perfect agreement (intraclass correlation coefficient, 0.93; 95% CI, 0.76-0.98). Retrospective IRR demonstrated strong agreement with an intraclass correlation coefficient of 0.77 (95% CI, 0.56-0.92). CONCLUSIONS The PSOM is a valid and reliable outcome measure for pediatric stroke. It is useful for retrospective scoring from health records and prospective serial longitudinal outcome assessments and is ideally suited for prospective clinical trials in pediatric stroke.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concurrent validity and reliability of retrospective scoring of the Pediatric National Institutes of Health Stroke Scale.

BACKGROUND AND PURPOSE The Pediatric National Institutes of Health Stroke Scale (PedNIHSS), an adaptation of the adult National Institutes of Health Stroke Scale, is a quantitative measure of stroke severity shown to be reliable when scored prospectively. The ability to calculate the PedNIHSS score retrospectively would be invaluable in the conduct of observational pediatric stroke studies. The...

متن کامل

Reliability of the Persian Version of Canadian Occupational Performance Measure for Iranian Elderly Population

Objectives: The value of the client-centered approach for treating patients with various disabilities has been increasingly acknowledged. The aim of this study was to determine the test-retest reliability of the Persian version of the Canadian Occupational Performance Measure (COPM) as an individual outcome measure among Iranian elderly population. Methods: In this cross-sectional study, 60 ...

متن کامل

Validity of Modified Ashworth Scale as a Measure of Wrist Spasticity in Stroke Patients

Objectives: There are some controversies about the value of modified Ashworth Scale (MAS) for assessing spasticity. The goal of this study was to investigate if there is any correlation between scores obtained from MAS for wrist spasticity and electrophysiological recordings as the objective measure of spasticity. Methods: In this cross-sectional study, 34 stroke patients were employed. Wris...

متن کامل

Clinical assessment of activities of daily living in acute stroke: Validation of the Persian version of Katz Index

Background: Katz Index is a well-known index for assessing basic activities of daily living. The aim was to determine validity and reliability of the Katz Index in Iranian patients with acute stroke. Methods: Eighty-seven patients (56 male, 31 female) with acute stroke (1-30 days post-stroke) participated in this psychometric properties study. Interval time for retest was 14 days. All partic...

متن کامل

Test-retest reliability of Motricity Index strength assessments for lower extremity in post stroke hemiparesis

  Background: The Motricity Index was used to measure strength in upper and lower extremities after stroke. The weighted score based on the ordinal 6 point scale of Medical Research Council was used to measure maximal isometric muscle strength. There is dearth of articles dealing with the reliability of this method. Therefore, the aim of this study was to determine the test retest reliability o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 2012