Bispectral Index Monitoring in a Severe Comatose Patient During Surgery

نویسندگان

  • Susana Fernández Galinski
  • Enriqueta Barrera
  • Antonio Valls
  • Milagros Montero
  • Juan Carlos Alvarez
  • Fernando Escolano
چکیده

A comatose patient required a tracheostomy. His Glasgow Coma Score was 4 and he was intubated with mydriatic and isochoric pupils, without corneal and light reflexes. Two previous EEGs showed signs of severe and diffuse encephalopathy (arreactive delta and theta rhythms) and there were no somatosensory evoked potentials recordable at the scalp. When the tracheostomy procedure was carried out, the Bispectral Index (BIS) helped to titrate the hypnotic and analgesic requirements keeping the haemodynamic parameters stable. IMPLICATIONS STATEMENT A comatose patient had to undergo surgery. We guided the hypnotic and analgesic requirements by the bispectral index. The bispectral index (BIS) has been used in severely comatose patients as an assessment of the onset of brain death [1]. Moreover, in patients in a persistent vegetative state, BIS has helped to guide anaesthetic depth during surgery [2]. We show the clinical state, electrophysiological tests and the anaesthetic management of a patient in coma after cardiac arrest due to near drowning, who needed to undergo a tracheostomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

متن کامل

Color density spectral array of bilateral bispectral index system: Electroencephalographic correlate in comatose patients with nonconvulsive status epilepticus

PURPOSE to describe the characteristics of the color density spectral array (CDSA) of bilateral bispectral index (b-BIS) monitoring system in patients with comatose nonconvulsive status epilepticus (NCSE). We hypothesized that CDSA could be helpful for monitoring NCSE in critically subjects if continuous EEG (cEEG) is not available. METHODS we retrospectively analyzed comatose patients admitt...

متن کامل

Evaluation of Sedation for the Unconscious Patient: Are We Still Far Away?

In our daily practice in intensive care unit, one of the “cornerstones” is to achieve adequate sedation for every patient. Intensive care unit (ICU) patients are often sedated, and a good hypnotic monitoring is important to assure an optimal level of sedation for every patient. Sedation monitoring can be achieved using subjective or objective methods. The most recent recommendations on manageme...

متن کامل

DUPLICATE PUBLICATION: Comparison of entropy and bispectral index values during propofol induction.

OBJECTIVE To identify the entropy levels that would correspond to bispectral index (BIS) levels in general anesthesia (GA) induction in patients who will undergo elective lumbar disc surgery (LDS). METHODS Thirty cases who underwent LDS under GA were included in our study after obtaining patient consent and approval of the Ethics Committee of Afyon Kocatepe University Medical School, Afyonkar...

متن کامل

Sudden cerebral depression detected by bispectral index monitoring in cryptococcal meningitis with elevated near‐fatal cerebrospinal fluid pressure

Case An increase in cerebrospinal fluid pressure (CSFP) is usually prominent in cryptococcal meningitis, which has a high mortality rate, so aggressive management to control CSFP is crucial. In this case, a 40-year-old-man survived cryptococcal meningitis treated with continuous spinal drainage under bispectral index (BIS) monitoring. He unexpectedly showed hypertension, went into a coma, and e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007