The impact of activating source dwell positions outside the CTV on the dose to treated normal tissue volumes in TRUS guided 3D conformal interstitial HDR brachytherapy of prostate cancer

نویسندگان

  • Leif Karlsson
  • Per Thunberg
  • Bengt Johansson
  • Jan Persliden
چکیده

PURPOSE Dose coverage is crucial for successful treatment in mono-brachytherapy. Since few and very high dose fractions are used, there is an important balance between dwell positioning outside the clinical target volume (CTV) and possible damage on adjacent normal tissue. The purpose of this study was to evaluate the possibility of having dwell positions close to the CTV surface, while maintaining an acceptable dose distribution, and to investigate the robustness in terms of known geometrical uncertainties of the implant. MATERIAL AND METHODS This study included 37 patients who had received brachytherapy for prostate cancer as a monotherapy with the following schedules: 2 × 14 Gy or 3 × 11 Gy, each fraction separated by two weeks. The source dwell positions were activated 5 mm outside CTV. New optimizations were simulated for dwell positions at 3, 2, 1, and 0 mm. Inverse and graphical optimization were applied according to the relative dose constraints: V100 CTV ≥ 97%, Dmax, urethra ≤ 110%, and D10 rectal mucosa ≤ 65%. The V100, normal tissue outside CTV was used to evaluate dose variations caused by different dwell positions. Prostate geometries and dose distributions for the different dwell positions outside the CTV were used to investigate the impact on the CTV dose distribution due to geometrical uncertainties. RESULTS Both V100, CTV, and V100, normal tissue decreased, 98.6% to 92.2%, and 17 cm(3) to 9.0 cm(3), for dwell activation from 5 mm to 0 mm. The evaluation of both simulated longitudinal geometrical uncertainties and different source dwell activations implied that V100, CTV ranged from 98.6% to 86.3%. CONCLUSIONS It is possible to reduce the V100, normal tissue by decreasing the source dwell positions outside the CTV from 5 to 3 mm, while maintaining dose constraints. In combination with the estimated geometrical uncertainties, however, the source dwell positions need to be 5 mm from the surface in order to maintain a robust implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The emerging role of high-dose-rate (HDR) brachytherapy as monotherapy for prostate cancer

High-dose-rate (HDR) brachytherapy as monotherapy is a comparatively new brachytherapy procedure for prostate cancer. In addition to the intrinsic advantages of brachytherapy, including radiation dose concentration to the tumor and rapid dose fall-off at the surrounding normal tissue, HDR brachytherapy can yield a more homogeneous and conformal dose distribution through image-based decisions fo...

متن کامل

SU-E-T-430: Evaluation of Inverse Optimization in Brachytherapy for Locally Advanced Cervix Cancer.

PURPOSE Brachytherapy is a vital part of treating locally advanced cervix cancer. Point-based 2D treatment planning is conventionally used. New CT/MRI-compatible applicators for HDR brachytherapy make 3D conformal planning possible. GEC-ESTRO endorsed the EMBRACE (intErnational study on MRI-guided BRachytherapy in locally Advanced CErvical cancer) protocol which recommends standard-plan-based m...

متن کامل

Independent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader

Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...

متن کامل

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014