Influence of atrial systole on the Frank-Starling relation and the end-diastolic pressure-diameter relation of the left ventricle.

نویسندگان

  • T Linderer
  • K Chatterjee
  • W W Parmley
  • R E Sievers
  • S A Glantz
  • J V Tyberg
چکیده

The influence of atrial systole on the left ventricular function curve (stroke volume vs end-diastolic pressure or end-diastolic diameter) and on the left ventricular end-diastolic pressure diameter relation was studied in nine anesthetized, open-chest dogs whose atrioventricular (AV) node had been completely blocked. Measurements were made during volume loading with the pericardium closed and opened and during alternate AV sequential pacing (to permit atrial contribution to ventricular filling) and AV simultaneous pacing (to prevent atrial contribution). When the pericardium was closed, withdrawal of the atrial contribution shifted the stroke-volume end-diastolic pressure relation downward, but did not shift the stroke volume-end-diastolic diameter relation, i.e., it reduced stroke volume for a given end-diastolic pressure according to a reduction in end-diastolic volume. The downward shift of the stroke volume-end-diastolic pressure relation was caused by an upward shift of the end-diastolic pressure-diameter relation, which, for a given end-diastolic pressure, resulted in a smaller end-diastolic diameter and, thus, in a smaller stroke volume. The reason for the upward shift in the end-diastolic pressure-diameter relation was that the atrium remained full and thus increased pericardial pressure by increasing pericardial volume. Opening the pericardium shifted the end-diastolic pressure-diameter relation downward and to the right, shifted the stroke volume-end-diastolic diameter relation upward and abolished the effect of withdrawal of the atrial contribution on these curves. We conclude that in the presence of an intact pericardium, atrial systole shifts the stroke volume-end-diastolic pressure relation because it shifts the end-diastolic pressure-diameter relation and it improves left ventricular performance by increasing preload.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanoelectric feedback does not contribute to the Frank-Starling relation in the rat and guinea pig heart

Abstract: Mechanoelectric feedback (MEF) is the process by which mechanical forces on the myocardium can alter its electrical properties. The effect can be large enough to induce ectopic beats or fibrillation. However, the role of MEF at physiological levels of mechanical stress is not clear. We have investigated alteration in action potential morphology in rat and guinea pig ventricle and in r...

متن کامل

Analysis of the Underlying Mechanism of Frank-Starling Law of a Constructive Hemodynamics Model

Abstract— Frank-Starling law, which describes a relation between cardiac contraction energy and end-diastolic volume, is of importance, but the detailed mechanism is not quantitatively understood yet. In this paper, the mechanism of a linear relation between end-diastolic volume and end-systolic pressure as a part of Frank-Starling law is analyzed by means of computer simulation. A hemodynamics...

متن کامل

Contractile performance of the hypertrophied ventricle in patients with systemic hypertension.

To assess the contractile state of the hypertrophied ventricle induced by long-standing systemic hypertension in 22 patients, we used echocardiography for the measurement of the ventricular diameter and posterior wall thickness, together with simultaneous recording of brachial arterial pressure. Meridional wall stress (WSt) was used for the expression of the force per unit cross-sectional area....

متن کامل

Dynamic determinants of letf ventricular diastolic pressure-volume relations in man.

Left ventricular (LV) diastolic pressure (P), volume (V), and rate of change of volume (dV/dt) were determined at 16.7 msec intervals in 17 patients (simultaneous micromanometer and single plane volume angiography). Four patients had mitral stenosis with atrial fibrillation and 13 patients (three normal, two congestive cardiomyophathy, three LV hypertrophy, and five coronary artery disease) wer...

متن کامل

Diastolic dysfunction beyond distensibility: adverse effects of ventricular dilatation.

Diastolic function has conventionally been assessed on the basis of the LV end-diastolic pressure-volume relation (Figure 1). A shift of this curve upward and to the left (curve A, Figure 1) has been considered to be the hallmark of diastolic dysfunction. In this situation, each LV end-diastolic volume is associated with a higher end-diastolic pressure, and therefore, the ventricle is less dist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 67 5  شماره 

صفحات  -

تاریخ انتشار 1983