Dynamic 13N-ammonia PET: a new imaging method to diagnose hypopituitarism.

نویسندگان

  • Zhang Xiangsong
  • Yue Dianchao
  • Tang Anwu
چکیده

UNLABELLED We have developed a new imaging method to evaluate the blood perfusion and ammonia metabolism of the pituitary gland, and we preliminarily assessed its role in the diagnosis of hypopituitarism. METHODS Six female healthy volunteers (age range, 20-46 y) and 6 female patients (age range, 23-42 y) were enrolled in this study. Dynamic (13)N-NH(3) PET was performed. Time-activity curves for the pituitary gland and internal carotid artery were generated by setting regions of interest on the transverse planes of the pituitary gland. The standardized uptake value of the pituitary gland, the radioactive ratio of pituitary to thalamus (P/T), and the first-pass uptake rate of ammonia in the pituitary gland were calculated. RESULTS (13)N-Ammonia was extracted rapidly by pituitary tissue in the first 120 s after injection and trapped in pituitary tissue in the healthy volunteers. Three to 20 min after injection, the pituitary gland was clearly seen in the healthy volunteers, and the mean (+/-SD) size of the pituitary gland on (13)N-ammonia PET images was (1.09 +/- 0.17 cm) x (1.08 +/- 0.14 cm) x (1.12 +/- 0.09 cm). However, in patients with hypopituitarism, the first-pass uptake rate of ammonia in the pituitary gland was significantly lower than that in healthy volunteers (0.35 +/- 0.10 vs. 0.75 +/- 0.07). On images of patients, the pituitary gland was absent or could not clearly be found, was small or malformed, and showed significantly lower uptake of (13)N-NH(3) than in healthy volunteers (standardized uptake value, 1.15 +/- 0.34 vs. 3.74 +/- 1.44; P/T, 0.65 +/- 0.23 vs. 1.24 +/- 0.34). CONCLUSION Dynamic (13)N-ammonia PET can provide information on blood perfusion and metabolism of the pituitary gland and is useful in early monitoring of damage to the pituitary gland and in diagnosing hypopituitarism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided in...

متن کامل

The effect of metabolic milieu on cardiac PET imaging using fluorine-18-deoxyglucose and nitrogen-13-ammonia in normal volunteers.

Cardiac PET imaging using 13N-ammonia and 18FDG was performed on 17 normal volunteers in the glucose-loaded and fasted states. PET images (glucose-loaded and fasted) were subjected to qualitative visual analysis using the descriptors: image quality, FDG blood-pool activity, ammonia lung field activity, and clinical interpretability. Glucose-loaded studies had better image quality, diminished FD...

متن کامل

Quantification of Absolute Myocardial Perfusion With Dynamic Positron Emission Tomography

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided in...

متن کامل

The combination of 13N-ammonia and 18F-FDG whole-body PET/CT on the same day for diagnosis of advanced prostate cancer

PURPOSE The aim of the study was to evaluate the efficacy of 13N-ammonia and 18F-fluorodeoxyglucose (18F-FDG) PET performed on the same day in the detection of advanced prostate cancer (PC) and its metastases. PATIENTS AND METHODS Twenty-six patients with high-risk PC [Gleason score 8-10 or prostate-specific antigen (PSA)> 20 ng/ml or clinical tumor extension ≥ T2c] were recruited into the st...

متن کامل

Gated cardiac 13N-NH3 PET for assessment of left ventricular volumes, mass, and ejection fraction: comparison with electrocardiography-gated 18F-FDG PET.

UNLABELLED The purpose of this study was to evaluate myocardial electrocardiography (ECG)-gated 13N-ammonia (13N-NH3) PET for the assessment of cardiac end-diastolic volume (EDV), cardiac end-systolic volume (ESV), left ventricular (LV) myocardial mass (LVMM), and LV ejection fraction (LVEF) with gated 18F-FDG PET as a reference method. METHODS ECG-gated 13N-NH3 and 18F-FDG scans were perform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2005