High Efficiency R-134a Compressor for Domestic Refrigerator
نویسندگان
چکیده
Because of high growth in economy and rapid increase in energy consumption , the government has made efforts to resolve the difficulties of the shortage of energy by restricting the amount of electrical energy consumption for home electrical products and several products consuming energy. Especially, the rules specified how the amount of electrical energy consumption was tested is expected to revise since 1996,and so the situation in grade expressed the efficient consumption of energy has been developed unfavorably since the electrical energy consumption per month was measured more 30% in amount than that used to be when testing the amount of electrical energy consumption for the same model of a refrigerator in according to the revised rules. INTRODUCTION In general, a compressor which consists of the heart of a refrigerator, a heater which removes frost,and a fan-motor which can distribute chill equally are considered as the main causes of consumption input in a refrigerator. Among the above components, improving the energy efficiency ratio of a compressor that has occupied 80 through 85 percent of the total electrical energy can decrease the amount of electrical energy consumption for a refrigerator. Therefore, we want to specify the studied and developed results about the high efficiency of the reciprocating type of a compressor for R-134a. HOW TO PROGRESS C.O.P (Coefficient of performance) In general, in order to progress the efficient of a compressor for a refrigerator, each element such as volume efficiency, compression efficiency,mechanical efficiency and motor efficiency shall be improved. In order to achieve the high efficiency of a compressor as the above specified contents, the cooling capacity shall be increased and the consumption input shall be decreased. So, we can make the cooling capacity be enhanced up to 15% and E. E. R be enhanced up to 9% in contrast with the existing R-12 model by selecting the items which the high efficient effects are anticipated and handling theory with experimental data together on the basis of the above specified theory.
منابع مشابه
The Simulation and Design of a High Efficiency, Lubricant Free, Linear Compressor for a Domestic Refrigerator
The first phase of a project at Sunpower, Inc. sponsored by the EPA is described. The program involves the design, computer simulation and fabrication of a high efficiency linear compressor for application in domestic refrigeration. The use of a high efficiency electric motor and non-contact operation can dramatically reduce the electrical and friction losses associated with crank compressors. ...
متن کاملCost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant
This paper presents a cost-effective method to increase the COP and utility of a domestic refrigerator using R-134a refrigerant. A cabin was installed on the top of a domestic refrigerator with condenser coils of refrigerator serving as heating coils inside the cabin. Known quantity of water was heated by the condenser coils (due to convection currents) thereby increasing the overall COP of the...
متن کاملReliability Study of HFC134a Compressor for Refrigerator
More than one year has passed since refrigerant for refrigerator was changed from CFC12 to HFC134a. Long term reliability of refrigerator in HFC134a refrigerant system is mainly dependent on lubrication of moving parts of compressor and clogging of capillary tube. To maintain better practical reliability in components in compressor such as refrigeration lubricant,metallic materials and motor in...
متن کاملNew High Efficiency R-134a Compressor
Over the last thirty years, few changes have taken place in reciprocating refrigeration and freezer hermetic· compressors. Of course there have been design improvements and many new applications, but the basics have stayed the same. DOE requirements have brought new energy standards for 1993 and, with most of that work behind them, manufacturers of white goods are concentrating on alternate ref...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014