Optimal Power Transmission of Offshore Wind Power Using a VSC-HVdc Interconnection
نویسندگان
چکیده
High-voltage dc transmission based on voltage-source converter (VSC-HVdc) is quickly increasing its power rating, and it can be the most appropriate link for the connection of offshore wind farms (OWFs) to the grid in many locations. This paper presents a steady-state operation model to calculate the optimal power transmission of an OWF connected to the grid through a VSC-HVdc link. The wind turbines are based on doubly fed induction generators (DFIGs), and a detailed model of the internal OWF grid is considered in the model. The objective of the optimization problem is to maximize the active power output of the OWF, i.e., the reduction of losses, by considering the optimal reactive power allocation while taking into account the restrictions imposed by the available wind power, the reactive power capability of the DFIG, the DC link model, and the operating conditions. Realistic simulations are performed to evaluate the proposed model and to execute optimal operation analyses. The results show the effectiveness of the proposed method and demonstrate the advantages of using the reactive control performed by DFIG to achieve the optimal operation of the VSC-HVdc.
منابع مشابه
Review on Hybrid HVDC Technology for Integration of Offshore Wind Power Plant
VSC HVDC will be the most important approach for transmitting the power of large-scale offshore wind power plant in the near future. In recent literature, the feasibility of using hybrid type HVDC for offshore wind transmission has been discussed. A hybrid HVDC system has at one line commutated converter (LCC) at mainland and one voltage source converter (VSC) at offshore platform, which may in...
متن کاملHVDC Connection of Offshore Wind Parks: VSC vs LCC with STATCOM
It is now clear that the installation of offshore wind parks is the next step towards an even more widespread use of wind power. In what concerns the interconnection of remote offshore wind parks to the existing onshore grid, for distances over 50 km and/or installed capacities above 100 MW, High Voltage Direct Current (HVDC) technology seems to be more adequate than High Voltage Alternating Cu...
متن کاملDesign and Analysis of Dc Voltage Control of Multi-terminal Vsc- Hvdc Systems
DESIGN AND ANALYSIS OF DC VOLTAGE CONTROL OF MULTI-TERMINAL VSCHVDC SYSTEMS G.PURUSHOTHAM, S. FAHMEEDA PARVEEN, G.VENKATA SURESH BABU PG Student, 2 Assistant Professor, Associate Professor & HOD, Department of Electrical and Electronics Engineering SITS, Kadapa, Andhra Pradesh, India. _________________________________________________________________________ ABSTRACT: This paper discusses a mult...
متن کاملInternational Journal of Smart Grid and Clean Energy Control system for offshore wind power generation system with DFIG and VSC-based HVDC transmission
This paper proposes a fundamental and efficient control technique for introducing VSC (voltage source converter)based HVDC (high voltage direct current) transmission into a large-scale offshore wind power generation system with DFIGs (doubly-fed induction generators). The electric power from the offshore wind turbine DFIG is considerably fluctuating and unstable, and needs to be transmitted fro...
متن کاملNew Voltage Source Converter Topology for HVDC Grid Connection of Offshore Wind Farms
Large offshore wind farms are recently emerging as promising alternative power sources. Long distances between offshore generation and onshore distribution grid demand new solutions for their connection to the AC network. HVDC systems based on voltage source converters (VSC) are a promising alternative to conventional AC transmission above a certain cable length. This paper presents a new VSC t...
متن کامل