Manufacture of patient-specific vascular replicas for endovascular simulation using fast, low-cost method

نویسندگان

  • Naoki Kaneko
  • Toshihiro Mashiko
  • Taihei Ohnishi
  • Makoto Ohta
  • Katsunari Namba
  • Eiju Watanabe
  • Kensuke Kawai
چکیده

Patient-specific vascular replicas are essential to the simulation of endovascular treatment or for vascular research. The inside of silicone replica is required to be smooth for manipulating interventional devices without resistance. In this report, we demonstrate the fabrication of patient-specific silicone vessels with a low-cost desktop 3D printer. We show that the surface of an acrylonitrile butadiene styrene (ABS) model printed by the 3D printer can be smoothed by a single dipping in ABS solvent in a time-dependent manner, where a short dip has less effect on the shape of the model. The vascular mold is coated with transparent silicone and then the ABS mold is dissolved after the silicone is cured. Interventional devices can pass through the inside of the smoothed silicone vessel with lower pushing force compared to the vessel without smoothing. The material cost and time required to fabricate the silicone vessel is about USD $2 and 24 h, which is much lower than the current fabrication methods. This fast and low-cost method offers the possibility of testing strategies before attempting particularly difficult cases, while improving the training of endovascular therapy, enabling the trialing of new devices, and broadening the scope of vascular research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Store Separation using Low-cost CFD with Dynamic Meshing

The simulation of the store separation using the automatic coupling of dynamic equations with flow aerodynamics is addressed. The precision and cost (calculation time) were considered as comparators. The method used in the present research decreased the calculation cost while limiting the solution error within a specific and tolerable interval. The methods applied to model the aerodynamic force...

متن کامل

Design, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy

Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...

متن کامل

Using 3D printed models for planning and guidance during endovascular intervention: a technical advance.

Three-dimensional (3D) printing applications in medicine have been limited due to high cost and technical difficulty of creating 3D printed objects. It is not known whether patient-specific, hollow, small-caliber vascular models can be manufactured with 3D printing, and used for small vessel endoluminal testing of devices. Manufacture of anatomically accurate, patient-specific, small-caliber ar...

متن کامل

Transradial Neurointerventional Approach to Basilar Tip Aneurysm: Case Report and Technical Note

Cerebral angiography through transfemoral approach is preferred in most of the situation though in cardiovascular surgery transradial angiography is accounted as the superior standard. The present study aimed at presenting our early experience of transradial approach to cerebral angiography and intervention of a patient with basilar tip aneurysm that had inappropriate vasculature to perform rou...

متن کامل

Conservative management of superior vena cava injury due to hemodialysis catheter placement: A case report and literature review

We reported the case of a 78-year old woman with the inadvertent superior vena cava injury resulting from hemodialysis catheter placement. The catheter was placed through the left internal jugular vein. Hemodynamics were stable. The initial chest film illustrated an extraluminal catheter and mediastinal widening. The patient did not have hemothorax. Computed tomography venography also confirmed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016