Problems affecting performance of the fluorescent treponemal antibody-absorption test for syphilis.

نویسندگان

  • E F Hunter
  • M R Adams
  • L H Orrison
  • B J Pender
  • S A Larsen
چکیده

Immunofluorescent staining of Treponema pallidum was studied to clarify the effect of three factors on the results of the fluorescent treponemal antibody-absorption test: (i) heat inactivation of sera at 56 degrees C for 30 min before testing, (ii) use of multicircle slides, and (iii) tungsten illumination to visualize and assess unstained treponemes on reactive as well as nonreactive smears. It was found that serum inactivation before testing was not necessary for detection of immunoglobin G antibody, but an immunoglobulin M prozone was detected in unheated serum. On multicircle slides, it was demonstrated that a false-positive reaction could be obtained in 30 s at 37 and 25 degrees C if a smear where a nonreactive serum had been placed was crossed by a strongly reactive serum from another circle. Tungsten illumination proved necessary for correct assessment of unstained treponemes on all fluorescent treponemal antibody-aborption test smears, reactive or nonreactive. The possible role of these factors in incorrect fluorescent treponemal antibody-absorption test results is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of genital herpes on results of fluorescent treponemal antibody absorption test.

Both the fluorescent treponemal antibody absorption (FTS-ABS) test and Venereal Disease Laboratory (VDRL) test for syphilis were performed routinely on 113 men with histories of genital ulcerations. The difference in negative VDRL and borderline FTS-ABS results between patients with and without herpes simplex virus in their genital ulcers and no evidence of previous or untreated syphilis was no...

متن کامل

Antitreponemal IgE in early syphilis.

Using a solid-phase radioimmunoassay technique, mean serum IgE concentrations were found to be raised in patients with early syphilis. Antitreponemal specificity of the IgE response was investigated by the fluorescent treponemal antibody absorption test using a fluorescein-isothiocyanate-labelled antiserum against the Fc-fragment of human IgE. Validity of this test procedure was assessed by blo...

متن کامل

Field performance of a rapid point-of-care diagnostic test for antenatal syphilis screening in the Amazon region, Brazil.

We evaluated an immunochromatographic point-of-care (POC) syphilis test in 712 pregnant women under field conditions in remote communities of the Amazon region (Brazil), and identified risk factors for syphilis. Women were screened by POC test using whole blood obtained by fingerprick, the fluorescent treponemal antibody absorption (FTA-Abs) test as the gold standard and the Venereal Diseases R...

متن کامل

Evaluation of a Treponema pallidum enzyme immunoassay as a screening test for syphilis.

The CAPTIA Syphilis-G enzyme immunoassay for the detection of antibodies to Treponema pallidum was evaluated as a screening test for syphilis in comparison with the standard rapid plasma reagin (RPR) test. One thousand samples were tested, and the standard fluorescent treponemal antibody absorption test and the standard microhemmaglutination test were used to confirm the presence of treponemal ...

متن کامل

Reactivity of microhemagglutination, fluorescent treponemal antibody absorption, Venereal Disease Research Laboratory, and rapid plasma reagin tests in primary syphilis.

Seroreactivity of sera from 109 patients with first-infection primary syphilis was 98.2% in the fluorescent treponemal antibody absorption test, 92.7% in the rapid plasma reagin 18-mm circle card test, 72.5% in the microhemagglutination test (MHA-TP), and 72.5% in the Venereal Disease Research Laboratory test. Seroreactivity of sera from 18 patients with primary syphilis with documented previou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 1979