Audiometric evaluation short and medium term in cochlear implants.

نویسندگان

  • Laura R Alonso-Luján
  • Ileana Gutiérrez-Farfán
  • Francisco A Luna-Reyes
  • Laura E Chamlati-Aguirre
  • Alfredo Durand Rivera
چکیده

OBJECTIVE Our purpose is report the results of cochlear implant program in this Institute, since our first surgery from November 2007, until December 2012. MATERIAL AND METHODS A cross-sectional study, observational, descriptive, analyzing the information about thresholds before and after implantation, using patients files (diagnosis, onset of hearing loss, brainstem auditory evoked potential (BAEP), computed tomography (CT), magnetic resonance imaging (MRI), implanted ear, brand and model of cochlear implants (CI) and audiometric studies before and after the CI. RESULTS We report the evolution of 68 patients, age ranged 1 year 8 months to 39 years 3 months old. 94% patients (n = 64) had pre-lingual hearing loss being hereditary non-syndromic hearing loss the most common etiology (29.4%). 100% patients had auditory brainstem responses showing bilateral profound hearing loss, in the 77.9% type A tympanograms were obtained (Jerger's classification), and 100% had absence of stapedial reflexes and otoacoustic emissions with low reproducibility. CT reported as normal in 85.2% of patients, the findings: 5.8% had chronic mastoiditis changes, other findings reported in 1.4% of patients were: digastric right facial nerve, facial nerve canal dehiscence, enlarged vestibular aqueduct, occupation and poor pneumatization of mastoid air cells, lateral semicircular canals agenesis, incomplete partition of the cochlea with wide vestibular and vestibular aqueduct dilatation. Most frequent MR findings of skull with cerebellopontine angle approach were vascular loops of internal auditory canals unilaterally. In 10.2%, 55.8% of patients (n = 38) were implanted in the right ear, 56 (82.3%) with a CI from Advanced Bionics, HiRes 90K model, the remaining with Cochlear, Freedom and Nucleus 5 models. Developments in CI results by audiometric tests: prior to placement was 106.2 dB averages at frequencies assessed, one month later 62.4 dB, at 6 months 44 dB, and with satisfactory threshold 32.9 dB. 55.8% of patients (n = 38) with P + HiRes Fidelity 120 strategy, the remaining with Hires S + Fidelity 120, Hires S and ACE RE. DISCUSSION Audiology service proposed to place the CI in the worst ear by threshold in audiometric tests, the otolaryngology service proposed the best ear from anatomical point view. Implanted in the INR more Advanced Bionics CI faq frequently due to the donation by the insurance for a new generation. Hearing thresholds using CI have improved since activation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Working Memory, Auditory Perception and Speech Intelligibility in Cochlear Implanted Children of Elementary School

Objectives: This study examined the relationship between working and short-term memory performance, and their effects on cochlear implant outcomes (speech perception and speech production) in cochlear implanted children aged 7-13 years. The study also compared the memory performance of cochlear implanted children with their normal hearing peers. Methods: Thirty-one cochlear impl...

متن کامل

Transcanal cochleostomy in cochlear implant surgery: long-term results of a cohort study.

UNLABELLED The combined approach technique (CAT) is a variation of the classical the mastoidectomy-posterior tympanotomy technique (MPTA) that combines a transcanal approach to cochleostomy with a reduced posterior tympanotomy for insertion of electrodes. AIM To compare and evaluate long-term safety and effectiveness outcomes obtained with the CAT and with MPTA approach in patients submitted ...

متن کامل

Can routine office-based audiometry predict cochlear implant evaluation results?

OBJECTIVES/HYPOTHESIS Determining cochlear implant candidacy requires a specific sentence-level testing paradigm in best-aided conditions. Our objective was to determine if findings on routine audiometry could predict the results of a formal cochlear implant candidacy evaluation. We hypothesize that findings on routine audiometry will accurately predict cochlear implant evaluation results in th...

متن کامل

Comparison of Auditory Perception in Cochlear Implanted Children with and without Additional Disabilities

Background: The number of children with cochlear implants who have other difficulties such as attention deficiency and cerebral palsy has increased dramatically. Despite the need for information on the results of cochlear implantation in this group, the available literature is extremely limited. We, therefore, sought to compare the levels of auditory perception in children with cochlear implant...

متن کامل

Assessment of Short Term Chloroquine-Induced Ototoxicity in Malaria Patients

Objective: To evaluate the effects of chloroquine phosphate on cochlear function using clinical and audiometric studies when administered in regular doses and in the recommended regimens, for the treatment of malaria. Study design and setting: Prospective, cohort, observational study, with convenience sampling, in a tertiary care hospital. Methodology: All subjects proved or presumed to be suff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista de investigacion clinica; organo del Hospital de Enfermedades de la Nutricion

دوره 66 5  شماره 

صفحات  -

تاریخ انتشار 2014