AV Nodal Reentrant Tachycardia Causing Inappropriate ICD Shocks In A Patient With Arrhythmogenic RV Dysplasia
نویسندگان
چکیده
We report a patient with an implantable cardioverter defibrillator (ICD) for arrhythmogenic right ventricular dysplasia (ARVD) who received inappropriate shocks for atrioventricular node reentry tachycardia (AVRNT). Patient had multiple shocks for tachycardia with EGM characteristics of very short VA interval and CL of 300 msec. An electrophysiologic (EP) study reproducibly induced typical AVNRT with similar features. The slow AV nodal pathway ablation resolved the ICD shocks. Despite increasingly sophisticated discrimination algorithms available in modern ICDs, the ability to differentiate SVT from VT can be challenging. Our patient received inappropriate shocks for AVNRT. When device interrogation alone is not conclusive, an EP study may be necessary to determine the appropriate therapeutic course.
منابع مشابه
Catheter ablation of atrial tachyarrhythmias causing inappropriate implantable cardioverter-defibrillator shocks.
AIMS Inappropriate shocks have been an important issue post-implantable cardioverter-defibrillator (ICD) implantation. Moreover, inappropriate ICD shocks are associated with increased mortality. The objective of this study was to evaluate the feasibility of catheter ablation therapy for atrial tachyarrhythmias (ATa) responsible for inappropriate ICD shocks. METHODS AND RESULTS Among 108 conse...
متن کاملDual AV Nodal Nonreentrant Tachycardia Resulting in Inappropriate ICD Therapy in a Patient with Cardiac Sarcoidosis
Dual atrioventricular nodal nonreentrant tachycardia (DAVNNT) occurs due to concurrent antegrade conduction over fast and slow atrioventricular nodal pathways and is treated by slow pathway modification. We describe a unique case of a patient with cardiac sarcoidosis who received inappropriate ICD shocks for DAVNNT. Atrial and ventricular device electrograms satisfied both rate and V>A criteria...
متن کاملLong term results of cardioverter-defibrillator implantation in patients with right ventricular dysplasia and malignant ventricular tachyarrhythmias.
OBJECTIVE To study the outcome of patients with arrhythmogenic right ventricular dysplasia treated with an implantable cardioverter-defibrillator (ICD) for ventricular tachyarrhythmias complicated by haemodynamic collapse. DESIGN Observational study. SETTING University hospital. PATIENTS Nine consecutive patients (eight male, one female; mean (SD) age, 36 (18) years) with arrhythmogenic r...
متن کاملICD discrimination of SVT versus VT with 1:1 V-A conduction: A review of the literature.
Inappropriate ICD shocks are associated with increased mortality. They also impair patients' quality of life, increase hospitalizations, and raise health-care costs. Nearly 80% of inappropriate ICD shocks are caused by supraventricular tachycardia. Here we report the case of a patient who received a single-lead dual-chamber sensing ICD for primary prevention of sudden cardiac death and experien...
متن کاملEntrainment for distinguishing atypical atrioventricular node reentrant tachycardia from atrioventricular reentrant tachycardia over septal accessory pathways with long-RP [corrected] tachycardia.
BACKGROUND The response to right ventricular (RV) entrainment is useful to distinguish atypical AV node reentrant tachycardia from AV reentrant tachycardia using a septal accessory pathway. Whether entrainment can differentiate between AV node reentrant tachycardia and AV reentrant tachycardia in patients with long-RP tachycardia has not been systematically validated. METHODS AND RESULTS Twen...
متن کامل