Is it time for a Glidescope letter?
نویسنده
چکیده
1. Brower RG, Lanken PN, MacIntyre N, Matthay MA, Morris A, Ancukiewicz M, Schoenfeld D, Thompson BT: Higher versus lower positive end-expiratory pressures in patients with the acute respiratory distress syndrome. N Engl J Med 2004; 351:327–36 2. Meade MO, Cook DJ, Guyatt GH, Slutsky AS, Arabi YM, Cooper DJ, Davies AR, Hand LE, Zhou Q, Thabane L, Austin P, Lapinsky S, Baxter A, Russell J, Skrobik Y, Ronco JJ, Stewart TE: Ventilation strategy using low tidal volumes, recruitment maneuvers, and high positive end-expiratory pressure for acute lung injury and acute respiratory distress syndrome: A randomized controlled trial. JAMA 2008; 299:637–45 3. Mercat A, Richard JC, Vielle B, Jaber S, Osman D, Diehl JL, Lefrant JY, Prat G, Richecoeur J, Nieszkowska A, Gervais C, Baudot J, Bouadma L, Brochard L: Positive end-expiratory pressure setting in adults with acute lung injury and acute respiratory distress syndrome: A randomized controlled trial. JAMA 2008; 299: 646–55 4. Gattinoni L, Caironi P: Refining ventilatory treatment for acute lung injury and acute respiratory distress syndrome. JAMA 2008; 299:691–3 5. Phoenix SI, Paravastu S, Columb M, Vincent JL, Nirmalan M: Does a higher positive end expiratory pressure decrease mortality in acute respiratory distress syndrome? A systematic review and meta-analysis. ANESTHESIOLOGY 2009; 110: 1098–105 6. Buchman TG: Physiologic stability and physiologic state. J Trauma 1996; 41:599–605 7. Rixen D, Siegel JH, Friedman HP: “Sepsis/SIRS,” physiologic classification, severity stratification, relation to cytokine elaboration and outcome prediction in posttrauma critical illness. J Trauma 1996; 41:581–98
منابع مشابه
Whole blood: more than the sum of the parts.
In Reply: We thank Xue et al. for their recent letter regarding our recent article and are happy to respond to their questions and comments. Their first question related to the number of neonates included in the study. We had two neonates in our study; one was randomized to the GlideScope (Verathon Medical, Bothell, WA) and the other to direct laryngoscopy (Heine, Dover, NH). We routinely use a...
متن کاملمقایسه میزان موفقیت لوله گذاری تراشه بعد از آموزش با دو روش گلایدسکوپ و لارنگوسکوپ
Background: Tracheal intubation is one of the most essential skills employed by all healthcare providers, nevertheless novice intubators turn out to be less successful when they initially perform the intubation. Video- laryngoscopes (GlideScopes) are novel instruments able to increase the success rate of tracheal intubation training. The aim of this study was to compare the success rate of trac...
متن کاملGlidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis
INTRODUCTION The Glidescope(®) video-laryngoscopy appears to provide better glottic visualization than direct laryngoscopy. However, it remains unclear if it translates into increased success with intubation. METHODS We systematically searched electronic databases, conference abstracts, and article references. We included trials in humans comparing Glidescope(®) video-laryngoscopy to direct l...
متن کاملKnotting in peripherally inserted central catheters: more possible mechanisms.
References 1 Cooper RM. Use of a new video laryngoscope (GlideScope®) in the management of a difficult airway. Can J Anesth 2003; 50: 611–3. 2 Doyle DJ, Zura A, Ramachandran M. Videolaryngoscopy in the management of the difficult airway (Letter). Can J Anesth 2004; 51: 95. 3 Cooper RM. Videolaryngoscopy in the management of the difficult airway (Letter, reply). Can J Anesth 2004; 51: 95–6. 4 Ra...
متن کاملEvaluation of the GlideScope for tracheal intubation in patients with cervical spine immobilisation by a semi-rigid collar.
Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope and its dedicated stylet. ...
متن کاملNear-zero difficult tracheal intubation and tracheal intubation failure rate with the "Besta Airway Algorithm" and "Glidescope® in morbidly obese" (GLOBE).
BACKGROUND Unpredicted Difficult Tracheal Intubation (DTI) with Macintosh occurs frequently in obese patients. We investigated the incidence of DTI using an algorithm based on preoperative assessment with the El-Ganzouri Risk Index (EGRI) and Glidescope® routine use. METHODS We prospectively enrolled morbidly obese patients undergoing abdominal surgery. Patients were scheduled for Glidescope®...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 111 6 شماره
صفحات -
تاریخ انتشار 2009