Biosensor for direct determination of organophosphate nerve agents using recombinant Escherichia coli with surface-expressed organophosphorus hydrolase. 2. Fiber-optic microbial biosensor.
نویسندگان
چکیده
A fiber-optic microbial biosensor suitable for direct measurement of organophosphate nerve agents was developed. The unique features of this novel microbial biosensor were the recombinant Escherichia coli cells expressing the enzyme organophosphorus hydrolase on the cell surface and the optical detection of the products of enzyme-catalyzed organophosphate hydrolysis. The use of cells with the metabolic enzyme expressed on the cell surface as a biological sensing element provides advantages of no resistance to mass transport of the analyte and product across the cell membrane and low cost due to elimination of enzyme purification, over the conventional microbial biosensors based on cells expressing enzyme intracellularly and enzyme-based sensors, respectively. The use of an optical transducer allows the detection of different organophosphates in a mixture, presently not feasible with acetylcholinesterase-based biosensors. E. coli cells expressing organophosphorus hydrolase (OPH) on the cell surface were immobilized in low melting temperature agarose on a nylon membrane and attached to the common end of a bifurcated fiber-optic bundle. OPH-expressing E. coli cells catalyzed the hydrolysis of organophosphorus pesticides to form stoichiometric amounts of chromophoric products that absorb light at specific wavelengths. The backscattered radiation of the specific wavelength incident light was measured using a photomultiplier detector and correlated to the organophosphate concentration. The best sensitivity and response time were obtained using a sensor constructed with 1.5 mg of cells operating in pH 9, 50 mM HEPES buffer with 100 mM NaCl and 0.05 mM CoCl2 at 30 degrees C. At optimized conditions, the biosensor measured paraoxon, parathion, and coumaphos pesticides with high selectivity against triazine and carbamate pesticides in approximately 10 min. The lower detection limits were 3 microM for paraoxon and parathion and 5 microM for coumaphos. When stored in the buffer at 22 degrees C, the biosensor was stable for over a 1-month period and showed no decline in the response for over 75 repeated usages. The new fiber-optic microbial biosensor is an ideal tool for on-line monitoring of the detoxification process for organophosphate pesticides-contaminated wastewaters but may not be suitable for environmental monitoring.
منابع مشابه
Biosensor for direct determination of organophosphate nerve agents using recombinant Escherichia coli with surface-expressed organophosphorus hydrolase. 1. Potentiometric microbial electrode.
A potentiometric microbial biosensor for the direct measurement of organophosphate (OP) nerve agents was developed by modifying a pH electrode with an immobilized layer of Escherichia coli cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosporus pesticides to release protons, the concentration of which is proportional to the amount o...
متن کاملFiber-optic enzyme biosensor for direct determination of organophosphate nerve agents.
A fiber-optic enzyme biosensor for the direct measurement of organophosphate nerve agents was developed. The basic element of this biosensor is organophosphorus hydrolase immobilized on a nylon membrane and attached to the common end of a bifurcated optical fiber bundle. The enzyme catalyzes the hydrolysis of organophosphate compounds to form stoichiometric amounts of chromophoric products that...
متن کاملAmperometric microbial biosensor for direct determination of organophosphate pesticides using recombinant microorganism with surface expressed organophosphorus hydrolase.
An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parat...
متن کاملHighly sensitive and selective amperometric microbial biosensor for direct determination of p-nitrophenyl-substituted organophosphate nerve agents.
We report herein a whole cell-based amperometric biosensor for highly selective, highly sensitive, direct, single-step, rapid, and cost-effective determination of organophosphate pesticides with a p-nitrophenyl substituent. The biosensor was comprised of a p-nitrophenol degrader, Pseudomonas putida JS444, genetically engineered to express organophosphorus hydrolase (OPH) on the cell surface imm...
متن کاملBiosensor for Direct Determination of Fenitrothion and EPN Using Recombinant Pseudomonas putida JS444 with Surface Expressed Organophosphorus Hydrolase. 1. Modified Clark Oxygen Electrode
This paper reports a first microbial biosensor for rapid and cost-effective determination of organophosphorus pesticides fenitrothion and EPN. The biosensor consisted of recombinant PNP-degrading/oxidizing bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorus hydrolase (OPH) on its cell surface as biological sensing element and a dissolved oxygen electrode as the transduce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 70 23 شماره
صفحات -
تاریخ انتشار 1998