Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure.

نویسندگان

  • R A Payne
  • C N Symeonides
  • D J Webb
  • S R J Maxwell
چکیده

The arterial pulse-wave transit time can be measured between the ECG R-wave and the finger pulse (rPTT), and has been shown previously to have a linear correlation with blood pressure (BP). We hypothesized that the relationship between rPTT, preejection period (PEP; the R-wave/mechanical cardiac delay), and BP would vary with different vasoactive drugs. Twelve healthy men (mean age 22 yr) were studied. Beat-to-beat measurements were made of rPTT (using ECG and photoplethysmograph finger probe), intra-arterial radial pressure, PEP (using cardiac bioimpedance), and transit time minus PEP (pPTT). Four drugs (glyceryl trinitrate, angiotensin II, norepinephrine, salbutamol) were administered intravenously over 15 min, with stepped dosage increase every 5 min and a 25-min saline washout between agents. All subjects in all conditions had a negative linear correlation (R2 = 0.39) between rPTT and systolic BP (SBP), generally constant between different drugs, apart from four subjects who had a positive rPTT/SBP correlation with salbutamol. The 95% limits of agreement between measured and rPTT-predicted SBP were +/-17.0 mmHg. Beat-to-beat variability of rPTT showed better coherence with SBP variability than it did with heart rate variability (P < 0.001). PEP accounted for a substantial and variable proportion of rPTT (12-35%). Diastolic (DBP) and mean arterial BP (MAP) correlated poorly with rPTT (R2 = 0.02 and 0.08, respectively) but better with pPTT (rPTT corrected for PEP, R2 = 0.41 and 0.45, respectively). The 95% limits of agreement between measured and pPTT-predicted DBP were +/- 17.3 mmHg. In conclusion, the negative correlation between rPTT and SBP is generally constant, even with marked hemodynamic perturbations. However, the relationship is not reliable enough for rPTT to be used as a surrogate marker of SBP, although it may be useful in assessing BP variability. DBP and MAP cannot be predicted from rPTT without correction for PEP. The significant contribution of PEP to rPTT means that rPTT should not be used as a marker of purely vascular function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects.

1. Obstructive sleep apnoea and its variants often provoke hundreds of short arousals that lead to the most important symptom, disabling hypersomnolence. The measurement of sleep in these conditions requires the documentation of these short arousals and this is conventionally done by manual inspection of the sleeping EEG, a laborious procedure. 2. Other markers of 'arousal', that are easier to ...

متن کامل

Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia.

BACKGROUND Pulse transit time (PTT) measurement may provide rapidly available beat-to-beat cardiovascular information when conditions change quickly and routine invasive arterial pressure measurement is not justified, for example during obstetric spinal anaesthesia. Method. We obtained ethics approval for an observational study of PTT during the onset of spinal anaesthesia in patients having el...

متن کامل

Blood Pressure Estimation based on Pulse Transit Time and Compensation of Vertical Position

A chronically high blood pressure (BP) may lead to arteriosclerosis and consequently is a risk factor for apoplectic stroke and cardiac infarction – the main death causes in industrial countries. Hence, blood pressure recently has become one of the most relevant parameters for the assessment of a patients’ health status. For the purpose of a continuous monitoring of cardiovascular patients, we ...

متن کامل

Blood Pressure and Heart Rate Variabilities Estimation Using Ballistocardiography

In this work a blood pressure and heart rate variability estimation system is presented. Instead of merely using beat-to-beat time interval extracted from the electrocardiogram (ECG), it is also used finger photoplethysmography (PPG) and ballistocardiography (BCG) information to have three independent estimates of the heart rate variability. Since pulse arrival and transit times can be extracte...

متن کامل

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 100 1  شماره 

صفحات  -

تاریخ انتشار 2006