Quality assessment of blood glucose monitors in use outside the hospital laboratory.
نویسندگان
چکیده
The quality of analytical results required in clinical practice is generally dictated by analytical rather than clinical criteria. The increasing availability of analytical technology that can be used outside the hospital laboratory challenges this situation. In an attempt to highlight this dilemma one method of glucose analysis outside the laboratory has been assessed using a pilot external quality assessment scheme (EQAS) and the results have been compared with the performance of the same machines in the laboratory. In the laboratory reliable results were obtained when the Glucometer was used by experienced laboratory personnel giving a good correlation of results (r = 0.96) when compared with an automated method. The results of the EQAS revealed that 44% of hospital ward glucose estimations and 63% of general practice estimations would be considered unsatisfactory by conventional laboratory criteria--that is, greater than +/- 2 SD of the mean laboratory result. This level of performance must, however, be considered in relation to the number of times that a clinically misleading result is obtained. No analytical system should be used in clinical practice without a continuous, objective assessment of its performance.
منابع مشابه
Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?
Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...
متن کاملElectromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors
Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملI-4: External Quality Assessment - A Necessity in The Andrology Laboratory
Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 36 8 شماره
صفحات -
تاریخ انتشار 1983