Electrolyte-balanced heparin in blood gas syringes can introduce a significant bias in the measurement of positively charged electrolytes.

نویسندگان

  • Miranda van Berkel
  • Volkher Scharnhorst
چکیده

BACKGROUND Heparin binds positively charged electrolytes. In blood gas syringes, electrolyte-balanced heparin is used to prevent a negative bias in electrolyte concentrations. The potential pre-analytical errors introduced by blood gas syringes are largely unknown. Here, we evaluate electrolyte concentrations in non-anticoagulated blood compared with concentrations measured in electrolyte-balanced blood gas syringes. METHODS Venous blood was collected into plain tubes. Ionized calcium, potassium, sodium and hydrogen ions were analyzed directly using a blood gas analyzer and the remaining blood was collected into different blood gas syringes in random order: Preset (Becton Dickinson), Monovette (Sarstedt) and Pico 50-2 (Radiometer). RESULTS Ionized calcium and sodium concentrations were significantly lower in blood collected in Becton Dickinson and Sarstedt syringes compared to non-heparinized (NH) blood. The mean bias exceeded biological variation-based total allowable error, which in most cases leads to clinically misleading individual results. In contrast, ionized calcium concentrations in blood collected in Pico 50-2 syringes were identical to values obtained from NH blood. Sodium showed a minor, yet statistically significant, bias. CONCLUSIONS Despite the fact that blood gas syringes now contain electrolyte-balanced heparin, one should be aware of the fact that these syringes can introduce pre-analytical bias in electrolyte concentrations. The extent of the bias differs between syringes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dry electrolyte-balanced heparinized syringes evaluated for determining ionized calcium and other electrolytes in whole blood.

By analyzing whole blood containing no anticoagulants (uncoagulated whole blood) immediately after collection, we evaluated the relative changes in the concentrations of ionized calcium and other electrolytes in whole blood collected in dry heparinized syringes and in serum prepared from blood collected in evacuated blood-collection tubes. Using these dry heparinized syringes, we collected and ...

متن کامل

Self-prepared heparinized syringes for measuring ionized magnesium in critical care patients.

We have compared ionized magnesium assays in the Nova 8 electrolyte analyser using dry balanced heparinized syringes and self-prepared heparinized syringes. Thirty blood specimens were obtained into syringes either operator-prepared with liquid sodium heparin or commercially manufactured dry balanced heparinized syringes. There was a good correlation between results from the two syringes. The m...

متن کامل

D-phenylalanyl-L-prolyl-L-arginine chloromethyl ketone (PPACK): alternative anticoagulant to heparin salts for blood gas and electrolyte specimens.

D-Phenylalanyl-L-prolyl-L-arginine chloromethyl ketone (PPACK), a selective thrombin inhibitor, was evaluated as an alternative anticoagulant to lithium heparin (LiHep) for blood gas and whole-blood electrolyte analyses. Initial studies in serum revealed a negative proportional bias for ionized calcium (iCa) concentration measured in the range of increasing concentrations of LiHep (-0.02 mmol/L...

متن کامل

Liquid Heparin Anticoagulant Produces More Negative Bias in the Determination of Ionized Magnesium than Ionized Calcium

The ionized calcium level in blood is known to be falsely decreased when self-prepared liquid heparin anticoagulant is used, due to dilution and binding effects. The effect of liquid heparin on the determination of ionized magnesium is not as well understood. We compared the effect of liquid sodium heparin on the determination of ionized calcium and magnesium in 44 clinical samples using two ty...

متن کامل

The effects of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin

INTRODUCTION We evaluated the effect of different syringe volume, needle size and sample volume on blood gas analysis in syringes washed with heparin. MATERIALS AND METHODS In this multi-step experimental study, percent dilution ratios (PDRs) and final heparin concentrations (FHCs) were calculated by gravimetric method for determining the effect of syringe volume (1, 2, 5 and 10 mL), needle s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 49 2  شماره 

صفحات  -

تاریخ انتشار 2011