Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners.

نویسندگان

  • Raj Shekhar
  • Vivek Walimbe
  • Shanker Raja
  • Vladimir Zagrodsky
  • Mangesh Kanvinde
  • Guiyun Wu
  • Bohdan Bybel
چکیده

UNLABELLED Registration and fusion of whole-body functional PET and anatomic CT is significant for accurate differentiation of viable tumors from benign masses, radiotherapy planning and monitoring treatment response, and cancer staging. Whole-body PET and CT acquired on separate scanners are misregistered because of differences in patient positions and orientations, couch shapes, and breathing protocols. Although a combined PET/CT scanner removes many of these misalignments, breathing-related nonrigid mismatches still persist. METHODS We have developed a new, fully automated normalized mutual information-based 3-dimensional elastic image registration technique that can accurately align whole-body PET and CT images acquired on stand-alone scanners as well as a combined PET/CT scanner. The algorithm morphs the PET image to align spatially with the CT image by generating an elastic transformation field by interpolating quaternions and translations from multiple 6-parameter rigid-body registrations, each obtained for hierarchically subdivided image subvolumes. Fifteen whole-body (spanning thorax and abdomen) PET/CT image pairs acquired separately and 5 image pairs acquired on a combined scanner were registered. The cases were selected on the basis of the availability of both CT and PET images, without any other screening criteria, such as a specific clinical condition or prognosis. A rigorous quantitative validation was performed by evaluating algorithm performance in the context of variability among 3 clinical experts in the identification of up to 32 homologous anatomic landmarks. RESULTS The average execution time was 75 and 45 min for images acquired using separate scanners and combined scanner, respectively. Visual inspection indicated improved matching of homologous structures in all cases. The mean registration accuracy (5.5 and 5.9 mm for images from separate scanners and combined scanner, respectively) was found comparable to the mean interexpert difference in landmark identification (5.6 +/- 2.4 and 6.6 +/- 3.4 mm, respectively). The variability in landmark identification did not show statistically significant changes on replacing any expert by the algorithm. CONCLUSION We have presented a new and automated elastic registration algorithm to correct for nonrigid misalignments in whole-body PET/CT images as well as improve the "mechanical" registration of a combined PET/CT scanner. The algorithm performance was on par with the average opinion of 3 experts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.

UNLABELLED Image registration and fusion of whole-body (18)F-FDG PET with thoracic CT would allow combination of anatomic detail from CT with functional PET information, which could lead to improved diagnosis or PET-based radiotherapy planning. METHODS We have designed a practical and fully automated algorithm for the elastic 3-dimensional image registration of whole-body PET and CT images, w...

متن کامل

PET/CT today and tomorrow.

UNLABELLED Accurate anatomic localization of functional abnormalities seen with PET is known to be problematic. Even though nonspecific tracers such as 18F-FDG visualize certain normal anatomic structures, the spatial resolution is generally inadequate for localization of pathology. Combining PET with a high-resolution anatomic imaging modality such as CT can resolve the localization issue, as ...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

A Novel Medical Image Registration Algorithm for Combined PET- CT Scanners Based on Improved Mutual Information of Feature Points

Accurate registration of PET and CT images is an important component in oncology, so we aim to develop an automated registration algorithm for PET and CT images acquired by different system. These two modalities offer affluent complementary information: CT provides specificity to anatomic findings, and PET provides precise localization of metabolic activity. In this paper, we proposed an improv...

متن کامل

MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration.

UNLABELLED For quantitative PET information, correction of tissue photon attenuation is mandatory. Generally in conventional PET, the attenuation map is obtained from a transmission scan, which uses a rotating radionuclide source, or from the CT scan in a combined PET/CT scanner. In the case of PET/MRI scanners currently under development, insufficient space for the rotating source exists; the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 46 9  شماره 

صفحات  -

تاریخ انتشار 2005