Noninvasive methods for quantitating blood time-activity curves from mouse PET images obtained with fluorine-18-fluorodeoxyglucose.

نویسندگان

  • L A Green
  • S S Gambhir
  • A Srinivasan
  • P K Banerjee
  • C K Hoh
  • S R Cherry
  • S Sharfstein
  • J R Barrio
  • H R Herschman
  • M E Phelps
چکیده

UNLABELLED The mouse model is currently being explored for various applications with PET imaging. Low resolution of current animal scanners relative to mouse size leads to difficulty in quantitating data from mouse PET images. We have, therefore, investigated methods for determining blood time-activity curves (TACs) from mouse PET studies done with fluorine-18-fluorodeoxyglucose (FDG). METHODS Eight mice were fasted, the tail vein was injected with 150-300 microCi of FDG and dynamic images were acquired with a CTI/Siemens (Knoxville, TN) animal tomograph for 64.5 min. Concurrently, 11-14 left ventricle (LV) blood samples were drawn directly from the LV chamber. Organ TACs were obtained by drawing circular regions of interest (ROIs) of various sizes on images of the heart, liver and brain. For each mouse, the FDG model parameter K = (K1 x k3)/(k2 + k3) was estimated by a Patlak algorithm with various estimates of the blood TAC and, as a reference tissue TAC, the brain TAC. RESULTS Most partial-volume-corrected heart ROI TACs overestimated the LV samples. Blood TACs from heart images produced statistically different estimates of K than did the LV samples. The liver image-derived blood TACs yielded estimates of K that were comparable to those yielded by the LV samples. Estimates of K determined with two directly sampled LV points in conjunction with the liver image-derived TAC were not statistically different from the estimates obtained with the LV samples. The size and location of ROIs on images of the liver minimally affected the TACs. CONCLUSION We have shown that it is experimentally possible to obtain a blood TAC from mouse studies by repeatedly sampling from the LV. We have also shown that images of the liver can be used to reliably estimate the blood TAC. Future FDG PET studies with the mouse model will benefit from this demonstrated ability to noninvasively quantitate blood TACs directly from FDG PET images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast imaging with fluorine-18-FDG PET: quantitative image analysis.

UNLABELLED This study evaluated various quantitative criteria for analysis of breast imaging with PET using the radiolabeled glucose analog 18F-fluorodeoxyglucose (FDG). METHODS In a prospective study, 73 patients with abnormal mammography or palpable breast masses scheduled for biopsy were investigated with PET. A total of 97 breast tumors were evaluated by histology, including 46 benign and...

متن کامل

Characterization of the image-derived carotid artery input function using independent component analysis for the quantitation of [18F] fluorodeoxyglucose positron emission tomography images Image-derived input function by ICA for FDG-PET

We previously developed a noninvasive technique for the quantification of fluorodeoxyglucose (FDG) positron emission tomography (PET) images using an imagederived input function obtained from a manually drawn carotid artery region. Here, we investigate the use of independent component analysis (ICA) for more objective identification of the carotid artery and surrounding tissue regions. Using FD...

متن کامل

Characterization of the image-derived carotid artery input function using independent component analysis

We previously developed a noninvasive technique for the quantification of fluorodeoxyglucose (FDG) positron emission tomography (PET) images using an image-derived input function obtained from a manually drawn carotid artery region. Here, we investigate the use of independent component analysis (ICA) for more objective identification of the carotid artery and surrounding tissue regions. Using F...

متن کامل

Occipital Hypometabolism on FDG PET/CT Scan in a Child with Hodgkin's Lymphoma

It is known that Fluorodeoxyglucose (FDG) Positron Emission/Computed Tomography (PET/CT) images may be helpful for evaluation of brain function in newborns. Here we described the fluorine-18 [18-F] FDG PET/CT imaging findings of encephalomalacia due to perinatal asphyxia in a child with refractory Hodgkin's Lymphoma (HL) who underwent PET/CT scan to stage the primary disease. Prominent hypometa...

متن کامل

[18F]-FDG positron emission tomography--an established clinical tool opening a new window into exercise physiology.

Positron emission tomography (PET) with [(18)F]-fluorodeoxyglucose (FDG) is an established clinical tool primarily used to diagnose and evaluate disease status in patients with cancer. PET imaging using FDG can be a highly valuable tool to investigate normal human physiology by providing a noninvasive, quantitative measure of glucose uptake into various cell types. Over the past years it has al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 1998