Comment on “Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery”
نویسندگان
چکیده
We readwith interest the article by Zanaty et al. “Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery” [1]. The authors presented a case series of 4 patients who had been treated with the pipeline embolization device for posterior communicating artery (PCoA) aneurysms across several institutions. However, their review of the previously published literature is incomplete and indeed this phenomenon has been described by our own series of 4 patients several months earlier [2]. Soon, thereafter, it was described by Tsang et al. [3], and followed by the recent article by Zanaty et al. These publications were likely in development simultaneously, but we wish to point out the previously published literature on the topic and reinforce the phenomenon observed across the 3 series. All 12 cases (4 in each series) involved posterior communicating artery aneurysms that incorporated a fetal origin of the posterior cerebral artery (PCA). The large flow demand of the fetal PCA causes flow across the aneurysm and into the distal PCA territory, preventing successful flow diversion. Without diversion of flow, the aneurysm remains patent and treatment fails. The same concept applies to other aneurysms incorporating “end vessels”; we recently presented this concept at the AANS 2016 meeting [4] and subsequently published it in Journal of Neurosurgery [5]. Competing Interests
منابع مشابه
Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery
The pipeline embolization device has emerged as an important endovascular option. This is in part due to safety, efficacy, and possibly the ability to shorten the operative time considerably. With this new technology, some limitations are emerging as experience accumulates. We report three cases of posterior communicating (PCOM) artery aneurysms associated with fetal posterior cerebral artery w...
متن کاملResponse to: Comment on “Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery”
1Department of Neurosurgery, University of Iowa Hospital and Clinics, 200 Hawkins Drive, Iowa City, IA 52242, USA 2Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, 3rd Floor, 901 Walnut Street, Philadelphia, PA 19107, USA 3Department of Neurosurgery, University of Virginia, Charlottesville, VA 22908, USA 4Department of Neurosurgery, Yale U...
متن کاملیافته های آنژیوگرافی در آنوریسم داخل جمجمه ای، بیمارستان امام، 79-1374
Background: This investigation was conducted in order to study angiographic findings in patients with cerebral aneurysm. Materials and Methods: The study conducted on 136 cases of ruptured cerebral aneurysms between 1995-2000 confirmed by means of 4-vessel cerebral angiography to get an insight to racial, geographic and environmental factors predisposing to the occurrence of subarachnoid hemorr...
متن کاملA Case of Ruptured Blood Blister-like Aneurysm Treated with Pipeline Embolization Device: Clinical Significance of Fetal-type Posterior Communicating Artery
Blood-blister like aneurysms (BBAs) are challenging lesions because of their wide fragile neck. Flow-diverting stents (FDSs), such as the Pipeline Embolization Device (PED), have been applied to treat BBAs less amenable to more established techniques of treatment. However, the use of FDSs, including the PED, in acute subarachnoid hemorrhage (SAH) still remains controversial. We report a case of...
متن کاملFailure of Flow Diverter Treatment of Intracranial Aneurysms Related to the Fetal-type Posterior Communicating Artery
PURPOSE The pipeline embolization device (PED) is a flow diverter that has shown promise in the treatment of intracranial aneurysms. Close to one-fifth of aneurysms, however, fail to occlude after PED placement. This study aims to identify anatomical features and clinicopathologic factors that may predispose failed aneurysm occlusion with the PED. MATERIALS AND METHODS We retrospectively revi...