ALMA Memo 402 Illumination Taper Misalignment and Its Calibration

نویسنده

  • M. A. Holdaway
چکیده

The alignment of the tapered illumination with the antenna's primary dish will not be perfect, and for ALMA has been speci ed as having an rms error of 0.1 dish radii at all frequencies, and the resulting image errors are therefore independent of frequency. If uncorrected, simulations indicate the e ects of this illumination o set will dominate both pointing and surface errors for ALMA's wide eld imaging at frequencies up to about 500 GHz. The main e ect of a shift in the tapered illumination on the dish is a phase gradient across the far eld voltage pattern, which is given by the Fourier transform of the illumination (neglecting surface errors). A secondary e ect will be a distortion in both the voltage pattern's amplitude and phase, caused by the asymmetric illumination pattern on the dish. The phase gradient in the voltage pattern is identical in e ect to an error in the baseline. However, the geometry of the baseline and the geometry of the voltage pattern phase gradient are di erent and will have di erent time dependences. The phase gradient can be e ectively treated by changing the (u; v) coordinates of each visibility to re ect the weighted antenna center accounting for the dish illumination o set. About 85% of the deviation of the o set far eld voltage pattern can be corrected by removing the phase gradient; the residual deviation is due to the asymmetric illumination, and is dominated by a bipolar pattern. This indicates that the majority of the e ect of the o set illumination can be removed by adjusting the (u; v) coordinates prior to imaging. The calibration parameters required to perform the (u; v) correction (ie, the phase gradient in the voltage pattern) should be constant with time for each antenna/feed. Thermal noise and atmospheric phase errors will not hamper the measurement of the phase gradient parameters at low frequencies, but will be of concern in determining these parameters at high frequencies. However, both types of error should average down if the calibration observations are performed correctly. Detailed numerical imaging simulations indicate that after correction of the (u; v) coordinates, the image quality is restored to the level expected when illuminations o sets are not present. In fact, often the image quality of the corrected images was better than when illuminations o sets are not present. This paradoxical result may be explained by the fact that feed leg and subre ector blockage were also included in the simulations. Without the illumination o sets, all antennas' voltage patterns are a ected in the same way by the feed legs, resulting in low level asymmetric side lobes that are not re ected in the symmetric beam model. However, the a ects of the random asymmetric illuminations of the di erent

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EVLA Memo: #139 Plan for Imaging Algorithm Research and Development

Many scientific deliverables of the next generation radio telescopes require widefield imaging or high dynamic range imaging, or both. Some next generation telescopes nearing completion (EVLA and ALMA) indeed promise at least a ten-fold increase in the sensitivity compared to the existing telescopes. High imaging dynamic range requires removal of systematic errors to high accuracy and for long ...

متن کامل

The Dual - Load Calibration device revisited

Following ALMA memo 371, I re-investigate the dual load calibration scheme which has been proposed for ALMA. This memo improves on the requirements derived in memo 371 by using a better prediction for the atmospheric fluctuations at short time scales. It is shown that because of atmospheric properties and of the antenna geometry, a dual-load system located in the ALMA antenna subreflectors need...

متن کامل

Saturation by Noise and CW Signals in SIS Mixers

In ALMA Memo 321, Plambeck points out that saturation (gain compression) is likely to be a significant factor limiting the calibration accuracy of ALMA observations. In this memo, saturation by broadband noise and CW signals is analyzed for representative SIS receivers operating at different frequencies. Many SIS mixers in current use are expected to exhibit a significant degree of gain compres...

متن کامل

ALMA Memo XXX Bandpass Calibration for ALMA

This memo contains a detailed evaluation of the expected performance of the bandpass calibration for ALMA. We evaluate the limitations on the bandpass accuracy due to the imperfect knowledge of the atmospheric transmission. We show that the best bandpass accuracy is obtained when the amplitude calibration is applied in a single-load scheme. The proposed scheme is a variant of the so-called band...

متن کامل

ALMA Memo #303 Water Vapour Radiometers for ALMA

The JCMT-CSO single-baseline interferometer was the first to demonstrate phase correction using the 183 GHz line, using equipment built by Martina Wiedner, Richard Hills and colleagues. Only a limited quantity of data were gathered but the results (ALMA memo 252) were encouraging and suggested that even an uncooled system could provide effective phase calibration at submillimetre wavelengths. S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001