A waveguide-coupled thermally isolated radiometric source.
نویسندگان
چکیده
The design and validation of a dual polarization source for waveguide-coupled millimeter and sub-millimeter wave cryogenic sensors is presented. The thermal source is a waveguide mounted absorbing conical dielectric taper. The absorber is thermally isolated with a kinematic suspension that allows the guide to be heat sunk to the lowest bath temperature of the cryogenic system. This approach enables the thermal emission from the metallic waveguide walls to be subdominant to that from the source. The use of low thermal conductivity Kevlar threads for the kinematic mount effectively decouples the absorber from the sensor cold stage. Hence, the absorber can be heated to significantly higher temperatures than the sensor with negligible conductive loading. The kinematic suspension provides high mechanical repeatability and reliability with thermal cycling. A 33-50 GHz blackbody source demonstrates an emissivity of 0.999 over the full waveguide band where the dominant deviation from unity arises from the waveguide ohmic loss. The observed thermal time constant of the source is 40 s when the absorber temperature is 15 K. The specific heat of the lossy dielectric, MF-117, is well approximated by C(v)(T) = 0.12 T (2.06) mJ g(-1) K(-1) between 3.5 K and 15 K.
منابع مشابه
Modeling of Optical Waveguide Poling and Thermally Stimulated Discharge
AbsfracfA charge density and current density model of a waveguide system has been developed to explore the ef€ects of electric field electrode poling. An optical waveguide may be modeled during poling by considering the dielectric charge distribution, polarization charge distribution, and conduetion charge generated by the poling field. These charge distributions are the source of poling curren...
متن کاملRadiometric Method for Emissivity Retrieval in High Reflective Materials
High reflective materials in the microwave region play a very important role in the realization of antenna reflectors for a broad range of applications, including radiometry. These reflectors have a characteristic emissivity which needs to be characterized accurately in order to perform a correct radiometric calibration of the instrument. Such a characterization can be performed by using open r...
متن کاملDistributed feedback-distributed Bragg reflector coupled cavity laser with a Ti:(Fe:)Er:LiNbO3 waveguide.
A thermally fixed photorefractive Bragg grating is written in a single-mode Ti:Fe:Er:LiNbO3 channel waveguide and used to develop a distributed feedback-distributed Bragg reflector coupled cavity laser with a second broadband dielectric cavity mirror. The optically pumped (lambda(p) = 1480 nm, P = 130 mW) laser emits in single-frequency operation as much as 8 mW at lambda = 1557.2 nm with a slo...
متن کاملHigh performance photon-pair source based on a fiber-coupled periodically poled KTiOPO4 waveguide.
We demonstrate efficient generation of photon pairs at 1316 nm in a fiber-coupled type-II phase-matched Rb-indiffused waveguide in periodically poled KTiOPO(4). The integrated waveguide source has a pair production rate of 2 x 10(7)/s/mW in a 1.08-nm bandwidth, in good agreement with a theoretical model that takes into account the transversal momentum imparted on the phase matching function by ...
متن کاملAccurate Analysis of Dielectric Backed Planar Conducting Layers of Arbitrarily Shaped in a Rectangular Waveguide
The characteristics of dielectric backed planar conducting layers of arbitrarily shaped in a rectangular waveguide are calculated by means of coupled integral equation technique (CIET) which accurately takes higher order mode interactions. Equivalent structures for the accurate analysis whole structure are introduced in which magnetic surface currents are identified as the unknowns at the apert...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 84 4 شماره
صفحات -
تاریخ انتشار 2013