Experimental evaluation of ballistic hazards in imaging diagnostic center

نویسندگان

  • Jolanta Karpowicz
  • Krzysztof Gryz
چکیده

BACKGROUND Serious hazards for human health and life and devices in close proximity to the magnetic resonance scanners (MRI scanners) include the effects of being hit by ferromagnetic objects attracted by static magnetic field (SMF) produced by scanner magnet - the so-called ballistic hazards classified among indirect electromagnetic hazards. International safety guidelines and technical literature specify different SMF threshold values regarding ballistic hazards - e.g. 3 mT (directive 2004/40/EC, EN 60601-2-33), and 30 mT (BMAS 2009, directive proposal 2011). Investigations presented in this article were performed in order to experimentally verify SMF threshold for ballistic hazards near MRI scanners used in Poland. MATERIAL/METHODS Investigations were performed with the use of a laboratory source of SMF (0-30 mT) and MRI scanners of various types. The levels of SMF in which metal objects of various shapes and 0.4-500 g mass are moved by the field influence were investigated. The distance from the MRI scanners (0.2-3T) where hazards may occur were also investigated. RESULTS Objects investigated under laboratory conditions were moved by SMF of 2.2-15 mT magnetic flux density when they were freely suspended, but were moved by the SMF of 5.6-22 mT when they were placed on a smooth surface. Investigated objects were moved in fields of 3.5-40 mT by MRI scanners. Distances from scanner magnet cover, where ballistic hazards might occur are: up to 0.5 m for 0.2-0.3T scanners; up to 1.3 m for 0.5T scanners; up to 2.0 m for 1.5T scanners and up to 2.5 m for 3T scanners (at the front and back of the magnet). CONCLUSIONS It was shown that SMF of 3 mT magnetic flux density should be taken as the threshold for ballistic hazards. Such level is compatible with SMF limit value regarding occupational safety and health-protected areas/zones, where according to the Polish labor law the procedures of work environment inspection and prevention measures regarding indirect electromagnetic hazards should be applied. Presented results do not support the increase up to 30 mT of the SMF limit for protected area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevention of diagnostic errors in position of conus medullaris in adult patients

Background and aims: Finding the safe location of spinal cord for cerebrospinal fluid (CSF) during surgical procedures is very important due to its various nature for each patient as well as its potential peripheral nervous system hazards. The aim of this study was to find the relationship between the location of conus medullaris (CM) and gender, age and body mass index (BMI) in order to minimi...

متن کامل

Sensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging

  Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

Evaluation of Application of Chitosan/nano Sodium Selenite Biodegradable Film on Full thickness Excisional Wound Healing in Rats

Objective- This study aimed at evaluation of histopathological findings of application of chitosan- nano selenium biodegradable film on full thickness excisional wound healing in rats. Design- Experimental Study Animals- Seventy-two male Wistar rats Procedures- Animals were randomized into six groups of 12 animals each. Group I: Animals with created wounds and no...

متن کامل

Evaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography

    Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 78  شماره 

صفحات  -

تاریخ انتشار 2013