First results of carbon ion track structure imaging in low pressure gas
نویسنده
چکیده
The relative biological effectiveness (RBE) is an important parameter in heavy ion treatment planning. It is well known that the RBE does not only depend on the LET of a particle, but also on the ion sort.. This can be explained by the difference in the local ionisation distribution for different kind of ions, expressed by LET and radial ionisation distribution. Our goal is to measure these parameters with high spatial resolution and compare the results with track structure data obtained by Monte Carlo simulations of Krämer [1]. The experimental method is based on a time projection chamber with optical readout (Optical Avalanche Chamber, OPAC). OPAC is able to measure the spatial ionisation pattern of a particle crossing the interaction volume. The chamber is operated with triethylamine (TEA) vapour at a pressure of typically 10 hPa. A description of the experimental setup can be found in [2,3]. During the last year the detection system was modified for the experiments with heavy ions at the GSIfacilities. The data acquisition system had to be upgraded and the intensity dynamic of the recorded image was improved to 11 bit (instead of previously 8 bit). A new gating system of the image intensifier allows for selective capture of images from small slices of the 3-dimensional ionisation track in the interaction volume. In summer 2002 measurements were performed at SIS at GSI with C-ions. Starting with an initial ion energy of 400 MeV/u tracks of carbon ions traversing the chamber parallel to the projection plane were recorded. By means of an adjustable water column the beam energy was stepwise reduced to 300, 200, 100, 50, 30 MeV/u and finally close to Bragg peak energies. More than 1000 tracks for each energy were recorded and stored for later offline analysis. This large number was required to obtain sufficient statistical information on the ionisation density, especially far outside the track core, where only high energy delta electrons deposit energy. For example Fig.1 shows a track of a 400 MeV/u C ion (a) and one with energy close to the Bragg maximum of 0,7 MeV/u (b).
منابع مشابه
Experimental, Kinetics and Isotherm Modeling of Carbon Dioxide Adsorption with 13X Zeolite in a fixed bed column
In this work, zeolite 13X with porosity structure has been used as an adsorbent for adsorption of CO2 flue gas. The effect of operating conditions including pressure and time on adsorption capacity were investigated. The experiments conditions are constant temperature, the range of pressure 1 - 9 bar and the registration of adsorption capacity with passing of time. Experimental data were adjust...
متن کاملThermodynamical Studies of Irreversible Sorption of CO2 by Wyodak Coal
Differential scanning calorimetry (DSC), temperature programmed desorption mass spectrometry (TPD-MS) and small angle neutron scattering (SANS) were used to investigate CO2 uptake by the Wyodak coal. Adsorption of carbon dioxide on Wyodak coal was studied by DSC. The exotherms evident at low temperatures are associated with the uptake of CO2 suggesting that carbon diox...
متن کاملCalculation of total dose and dose equivalent distribution in the treatment of lung cancer using MR-guided carbon therapy
Nowadays, in order to improve the accuracy of treatment in radiation therapy, there are many attempts to use magnetic resonance imaging (MRI) due to the advantages of excellent soft tissue contrast and ultra-fast pulse sequences. On the other hand, carbon-ion radiation therapy is developing rapidly due to the benefits of greater relative biological effectiveness (RBE) and the application in the...
متن کاملSynthesis of Hard Carbon- Silicon Nanocomposite as Anode Active Material for Lithium-Ion Batteries
In this research, using phenolic resin as the precursor of carbon and various amounts of ethylene glycol as a pore former, porous samples of hard carbon were synthesized. Samples were characterized by x-ray diffraction (XRD) and N2 adsorption-desorption methods. Broad diffraction peaks represent the amorphous structure of samples. Moreover, the gas adsorption-desorption curves showed that the a...
متن کاملThe Drift Directional Dark Matter Detector and First Studies of the Head-tail Effect
Measurement of the direction of the elastic nuclear recoil track and ionization charge distribution along it, gives unique possibility for unambiguous detection of the dark matter WIMP particle. Within current radiation detection technologies only Time Projection Chambers filled with low pressure gas are capable of such measurement. Due to the character of the electronic and nuclear stopping po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003