Baseline reconstruction for localization of rapid ventricular tachycardia from body surface potential maps.

نویسندگان

  • Tommi Jokiniemi
  • Kim Simelius
  • Jukka Nenonen
  • Ikka Tierala
  • Lauri Toivonen
  • Toivo Katilal
چکیده

Determination of an accurate electrocardiographic (ECG) baseline is generally needed for localization of ventricular arrhythmias with body surface potential mapping (BSPM). We suggest a novel signal processing method for ECG baseline reconstruction during monomorphic ventricular tachycardias (VT). The method is based on an assumption that VT consists of similar ventricular extrasystolic beats with overlapping depolarization and repolarization. The sequential reconstruction algorithm utilizes information of small variations in the heart rate and yields a non-overlapping QRST-signal, provided that the measurement set-up has a high enough temporal resolution to avoid distortions due to sampling differences and misalignment of individual beats. The reconstructed QRST-signal is utilized to subtract overlapping T-waves from the QRS complexes during VT. The use of the method is demonstrated with clinically measured BSPM data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous localization of ectopic left ventricular activation sites by means of a two-dimensional representation of body surface QRS integral maps

By means of Karhunen-Loève transformation it is possible to represent electrocardiographic body surface QRS integral maps using only two coefficients while retaining more than 80% of information. These coefficients are computed for a number of mean paced QRS integral maps, which were acquired from well-defined ventricular segments and are contained in a database used for localization of the ori...

متن کامل

Electrocardiographic body surface mapping in patients with ventricular tachycardia. Assessment of utility in the identification of effective pharmacological therapy.

BACKGROUND Body surface maps of net QRST deflection areas (isointegrals) reflect regional ventricular repolarization properties. Vulnerability to ventricular tachyarrhythmias is associated with maps that feature multiple islands (extrema) of positive and negative values; such maps reflect regional disparity of ventricular recovery properties. The value of body surface mapping in prediction of t...

متن کامل

Assessment of Utility in the Identification of Effective Pharmacological Therapy

Background. Body surface maps of net QRST deflection areas (isointegrals) reflect regional ventricular repolarization properties. Vulnerability to ventricular tachyarrhythmias is associated with maps that feature multiple islands (extrema) of positive and negative values; such maps reflect regional disparity of ventricular recovery properties. The value of body surface mapping in prediction of ...

متن کامل

Resolution of pace mapping stimulus site separation using body surface potentials.

BACKGROUND Several studies have related 12-lead ECG waveform during ventricular tachycardia to ECG waveform during ventricular pacing to identify ablation sites for therapy of ventricular tachycardia. QRS isopotential maps and QRS isointegral maps derived from body surface isopotential maps have also been correlated with left ventricular pacing sites with the same objective. The comparison proc...

متن کامل

Clinical use of body surface potential mapping in cardiac arrhythmias.

Body surface potential maps have and certainly will have a very important role in the field of clinical arrhythmology, specifically for the localization of accessory pathways, for the detection of the origin of ventricular arrhythmias and for the identification of patients at risk of sudden death. In this particular setting, surface maps are certainly more useful than other more costly and soph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2003