Automated interstudy image registration technique for SPECT and PET.

نویسندگان

  • S Eberl
  • I Kanno
  • R R Fulton
  • A Ryan
  • B F Hutton
  • M J Fulham
چکیده

UNLABELLED We report the extended application of an automated computer technique for three-dimensional spatial registration of SPECT and PET studies. METHODS The technique iteratively reslices a misaligned data set until the sum of the absolute differences (SAD) from a reference data set is minimized. The registration accuracy was assessed in Hoffman brain phantom studies collected with known misalignments and transmission studies of a thorax phantom with fiducial markers. The SAD was compared with three other cost functions: stochastic sign change criterion, sum of products and standard deviation (s.d.) of ratios. In clinical neurological and myocardial perfusion studies, registration accuracy was estimated from the relative locations of landmarks in the reference and registered data sets. RESULTS Registration accuracy in the Hoffman brain phantom studies was -0.07 +/- 0.46 mm (mean +/- s.d.) for translations and -0.01 +/- 0.20 degrees for rotations, with maximum translation and rotation errors of 1.2 mm and 0.8 degree, respectively. The SAD was the most accurate and reliable cost function. Registration errors in the thorax phantom were 3.1 +/- 1.7 mm. Mean accuracy in the neurological studies, estimated from landmark pairs, was 2.0 +/- 1.1 mm for SPECT to SPECT and 1.8 +/- 1.1 mm for PET to SPECT registrations. Average registration accuracy in 201Tl myocardial perfusion studies was 2.1 +/- 1.2 mm. CONCLUSION Our registration method (a) provided accurate registrations for phantom and clinical SPECT and PET studies, (b) is fully automated, (c) simplifies comparison of data sets obtained at different times and with different modalities, and (d) can be applied retrospectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image registration accuracy of an in-house developed patient transport system for PET/CT+MR and SPECT+CT imaging.

OBJECTIVE The aim of this study was to investigate the registration accuracy of a newly developed patient shuttle system that can integrate different scanners by patient transfer without repositioning for 'hardware'-based image fusion. We aimed to assess the registration accuracy of image fusion in two different settings: a trimodality PET/CT+MR system and a SPECT+CT system. MATERIALS AND MET...

متن کامل

A Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information

Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...

متن کامل

Triple-Modality Normalized Mutual Information Based Medical Image Registration of Cardiac PET/CT and SPECT Images

An extension of the normalized mutual information similarity measurement was proposed to register cardiac PET/CT and SPECT images representing coronary artery disease in the heart. 23 PET/CT images obtained by a hybrid camera, and their corresponding SPECT were processed. The SPECT was registered to the PET/CT image pairs by a triple NMI based auto-registration. For validation and comparison an...

متن کامل

An interactive technique for three-dimensional image registration: validation for PET, SPECT, MRI and CT brain studies.

UNLABELLED A multipurpose three-dimensional registration technique was validated with PET, SPECT, CT and MRI scans, which had been obtained under normal clinical conditions. In contrast to fully automated procedures, this coregistration method is highly interactive, which has the advantage that it does not impose rigid restrictions by data type and by alterations in normal anatomy or brain func...

متن کامل

A comparative study of surface- and volume-based techniques for the automatic registration between CT and SPECT brain images.

Image registration of multimodality images is an essential task in numerous applications in three-dimensional medical image processing. Medical diagnosis can benefit from the complementary information in different modality images. Surface-based registration techniques, while still widely used, were succeeded by volume-based registration algorithms that appear to be theoretically advantageous in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 1996