A dual detector b-ray imaging probe with c-ray background suppression for use in intra-operative detection of radiolabeled tumors
نویسندگان
چکیده
The basic concepts for a dual detector b` imaging probe incorporating a method of c-ray background suppression were evaluated. The test devices consisted of a 1.2 cm2 b` imaging CaF 2 (Eu) scintillator disk optically coupled to a 1.7 mm thick, area-matched transparent diffuser disk, which in turn was coupled to sets of 2]2 or 4]4 mm2 by 10 mm long BGO, GSO or LSO scintillators, which acted as both c-detectors as well as light guides for the CaF 2 (Eu) scintillation light, which in turn are attached to a fiber optic bundle coupled to a multichannel photomultiplier. Pulse shape discrimination allowed identification of the detector of interaction and coincidence between the two detectors allowed selection of b`-only events. This type imaging detector system was shown to be capable of producing high-resolution images of b` distributions while suppressing the events due to the 511 keV annihilation radiation background. GSO was found to be the detector of choice for this application. ( 1998 Elsevier Science B.V. All rights reserved.
منابع مشابه
DESIGN CONSIDERATIONS AND INITIAL PERFORMANCE OF A 1.2cm/sup 2/ BETA IMAGING INTRA-OPERATIVE PROBE - Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
A novel small area beta (p') detector is under development for nuclear emission imaging of surgically exposed radiolabeled tumor beds. The imaging device consists of an 0.5 mm thick x 1.25 cm diameter CaF2(Eu) scintillator disk coupled to a rigid bundle of 19, 2 mm diameter x 5 cm long double clad optical fibers through a 1.7 mm polystyrene light diffuser. The detector size (1.2 cm2) was determ...
متن کاملW3: Intra-Operative Imaging and Brain Pathology
The Intraoperative MRI is of great importance in the surgical removal of gliomas or cranial base tumors. However, the sole use of a intraoperative MRI is problematic, so that a dual system has been developed to optimize the utilization of the equipment, which can be used both for neurosurgical patients and for outpatient or stationary Patients. Within the framework of the new head Center at the...
متن کاملبررسی امکان تشخیص اتوماتیک میکروکلسیم های بافت پستان با استفاده از تکنیک دو انرژی تصویربرداری اشعه ایکس جهت تشخیص زودرس سرطان پستان
Background and purpose: Dual-energy mammography technique is used for improving the accuracy of breast cancer diagnosis especially in dense breast cases and also detection of micro-calcifications which are early signs of breast cancer. The purpose of this study was to investigate the automatic separation feasibility of micro-calcification images in breast tissue images and evaluating its accura...
متن کاملRadiolabeling and Biodistribution of new dual modality nanoparticle probe in Nuclear Medicine
Introduction: Dual-modality contrast agents, such as radiolabeled nanoparticles, are promising candidates for a number of diagnostic applications, namely SPECT imaging with MR imaging. So the aim of study was evaluating potential of Chitosan-Coated Magnetic Nanoparticles(SPION) labeled with 99mTc as new Dual-modality probes for liver Imaging. Materials and Methods:</st...
متن کاملDESIGN CONSIDERATIONS AND INITIAL PERFORMANCE OF A 1.2 cm2 BETA IMAGING INTRA-OPERATIVE PROBE
A novel small area beta (p') detector is under development for nuclear emission imaging of surgically exposed, radiolabeled tumor beds. The imaging device front-end consists of a 0.5 mm thick by 1.25 cm diameter CaF,(Eu) scintillator disk coupled to a rigid bundle of 2 mm diameter double clad optical fibers through a polystyrene light diffuser. The detector area (1.2 cm2) was determined by the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1998