Long-term compliance with nasal continuous positive airway pressure therapy of obstructive sleep apnea.
نویسندگان
چکیده
In an attempt to identify predictors of long-term compliance with nasal continuous positive airway pressure (CPAP), we reviewed the records of 125 patients with obstructive sleep apnea (OSA) referred to our center for nasal CPAP trials. Severity of sleep apnea, sleep staging, daytime hypersomnolence, effectiveness of nasal CPAP, previous palatal surgery, and adverse reactions were compared in compliant and noncompliant patients. Nineteen patients did not tolerate a nasal CPAP trial in the laboratory or refused home nasal CPAP therapy. Ten patients were unavailable for follow-up. Of the remaining 96 patients, 23 (24 percent) had discontinued therapy, while 73 (76 percent) were still using nasal CPAP at 14.5 +/- 10.7 months (mean +/- SD). There were no statistically significant differences between the compliant and noncompliant patients in baseline apnea plus hypopnea index (AHI), baseline sleep staging, AHI while receiving nasal CPAP, sleep staging while receiving nasal CPAP, or frequency of adverse reactions during therapy. Severe daytime sleepiness was present in 65 of the 73 compliant patients and in 12 of the 23 noncompliant patients (p less than 0.05). Ten of 43 in the compliant group had previous palatal surgery compared with ten of 23 noncompliant patients (p less than 0.05). Our data confirm earlier observations in smaller samples that compliant and noncompliant patients have equally severe sleep apnea and good initial responses to nasal CPAP. Long-term compliance with nasal CPAP may be associated with the severity of daytime hypersomnolence on presentation. Previous palatal surgery was more frequent in patients who did not tolerate long-term nasal CPAP therapy.
منابع مشابه
Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications.
Treatment of obstructive sleep apnea with nasal continuous positive airway pressure mandates simultaneous increases of both inspiratory and expiratory positive airway pressures to eliminate apneas as well as nonapneic oxyhemoglobin desaturation events. We hypothesized that the forces acting to collapse the upper airway during inspiration and expiration are of different magnitudes and that obstr...
متن کاملObjective patient compliance in long-term use of nCPAP.
Concerns remain regarding patient compliance with nasal continuous positive airway pressure (nCPAP). Poor objective compliance during the first months of treatment has been reported, but no data are available among chronically treated patients. Use of nCPAP, in 17 chronically treated obstructive sleep apnoea patients (820+/-262 days) was evaluated objectively using a pressure monitor (MC+; Sefa...
متن کاملPredictive factors of long-term compliance with nasal continuous positive airway pressure treatment in sleep apnea syndrome.
The long-term acceptability of treatment with nasal continuous positive airway pressure (CPAP) was studied prospectively in 44 patients with obstructive sleep apnea syndrome. At 14 months on the average after starting treatment with CPAP, 30 patients (68 percent) were found to be compliant (characterized by use of the apparatus every night throughout the night, for more than 5 h per night). The...
متن کاملFactors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach
Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...
متن کاملInterventions to improve compliance in sleep apnea patients previously non-compliant with continuous positive airway pressure.
STUDY OBJECTIVES Despite widespread agreement that continuous positive airway pressure is effective therapy for obstructive sleep apnea, it is estimated that 50% of patients recommended for therapy are noncompliant 1 year later. Interventions to improve compliance in such patients have not been studied. We evaluated a 2 phase intervention program to improve compliance in sleep apnea patients pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 97 1 شماره
صفحات -
تاریخ انتشار 1990