Image distortion in thermoacoustic tomography caused by microwave diffraction.

نویسندگان

  • Changhui Li
  • Manojit Pramanik
  • Geng Ku
  • Lihong V Wang
چکیده

We report an intrinsic image distortion in microwave-induced thermoacoustic tomography. The distortion, due to microwave diffraction in the object to be imaged, leads to nonuniform excitation of acoustic pressure during microwave illumination. Both numerical simulations and phantom experiments demonstrate this phenomenon. A method of partial correction is also provided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of acoustic heterogeneities on transcranial brain imaging with microwave-induced thermoacoustic tomography.

The effects of acoustic heterogeneities on transcranial brain imaging with microwave-induced thermoacoustic tomography were studied. A numerical model for calculating the propagation of thermoacoustic waves through the skull was developed and experimentally examined. The model takes into account wave reflection and refraction at the skull surfaces and therefore provides improved accuracy for th...

متن کامل

Thermoacoustic tomography with correction for acoustic speed variations.

Thermoacoustic tomography (TAT) is a technique that measures microwave-induced thermoacoustic waves at the boundary of biological tissue and generates images of internal microwave absorption distributions from the measurements. Existing reconstruction algorithms for TAT are based on the assumption that the acoustic properties in the tissue are homogeneous. Biological tissue, however, has hetero...

متن کامل

Scanning thermoacoustic tomography in biological tissue.

Microwave-induced thermoacoustic tomography was explored to image biological tissue. Short microwave pulses irradiated tissue to generate acoustic waves by thermoelastic expansion. The microwave-induced thermoacoustic waves were detected with a focused ultrasonic transducer. Each time-domain signal from the ultrasonic transducer represented a one-dimensional image along the acoustic axis of the...

متن کامل

Microwave-induced thermoacoustic tomography: reconstruction by synthetic aperture.

We have applied the synthetic-aperture method to linear-scanning microwave-induced thermoacoustic tomography in biological tissues. A nonfocused ultrasonic transducer was used to receive thermoacoustic signals, to which the delay-and-sum algorithm was applied for image reconstruction. We greatly improved the lateral resolution of images and acquired a clear view of the circular boundaries of bu...

متن کامل

Signal processing in scanning thermoacoustic tomography in biological tissues.

Microwave-induced thermoacoustic tomography was explored to image biological tissues. Short microwave pulses irradiated tissues to generate acoustic waves by thermoelastic expansion. The microwave-induced thermoacoustic waves were detected with a focused ultrasonic transducer to obtain two-dimensional tomographic images of biological tissues. The dependence of the axial and the lateral resoluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 77 3 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2008