Mechanical Dyssynchrony is Similar in Different Patterns of Left Bundle-Branch Block

نویسندگان

  • Rodrigo Bellio de Mattos Barretto
  • Leopoldo Soares Piegas
  • Jorge Eduardo Assef
  • José Francisco Melo
  • Thiago Uchoa Resende
  • Dalmo Antonio Moreira
  • David Costa LeBihan
  • Francisco Faustino França
  • Romeu Sérgio Meneghelo
  • Amanda Guerra Moraes Rego Sousa
چکیده

BACKGROUND Left bundle-branch block (LBBB) and the presence of systolic dysfunction are the major indications for cardiac resynchronization therapy (CRT). Mechanical ventricular dyssynchrony on echocardiography can help identify patients responsive to CRT. Left bundle-branch block can have different morphologic patterns. OBJECTIVE To compare the prevalence of mechanical dyssynchrony in different patterns of LBBB in patients with left systolic dysfunction. METHODS This study assessed 48 patients with ejection fraction (EF) < 40% and LBBB consecutively referred for dyssynchrony analysis. Conventional echocardiography and mechanical dyssynchrony analysis were performed, interventricular and intraventricular, with ten known methods, using M mode, Doppler and tissue Doppler imaging, isolated or combined. The LBBB morphology was categorized according to left electrical axis deviation in the frontal plane and QRS duration > 150 ms. RESULTS The patients' mean age was 60 ± 11 years, 24 were males, and mean EF was 29% ± 7%. Thirty-two had QRS > 150 ms, and22, an electrical axis between -30º and +90º. Interventricular dyssynchrony was identified in 73% of the patients, while intraventricular dyssynchrony, in 37%-98%. Patients with QRS > 150 ms had larger left atrium and ventricle, and lower EF (p < 0.05). Left electrical axis deviation associated with worse diastolic function and greater atrial diameter. Interventricular and intraventricular mechanical dyssynchrony (ten methods) was similar in the different LBBB patterns (p = ns). CONCLUSION In the two different electrocardiographic patterns of LBBB analyzed, no difference regarding the presence of mechanical dyssynchrony was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diminished left ventricular dyssynchrony and impact of resynchronization in failing hearts with right versus left bundle branch block.

OBJECTIVES We compared mechanical dyssynchrony and the impact of cardiac resynchronization therapy (CRT) in failing hearts with a pure right (RBBB) versus left bundle branch block (LBBB). BACKGROUND Cardiac resynchronization therapy is effective for treating failing hearts with conduction delay and discoordinate contraction. Most data pertain to LBBB delays. With RBBB, the lateral wall contra...

متن کامل

Left ventricular dyssynchrony from right ventricular pacing depends on intraventricular conduction pattern in intrinsic rhythm.

AIMS Right ventricular pacing (RVP) prolongs ventricular activation and may induce mechanical dyssynchrony. We hypothesized that the severity of RVP-associated ventricular mechanical dyssynchrony may depend on the intrinsic intraventricular conduction pattern. METHODS AND RESULTS Sixty-five patients with a single- or dual-chamber RV pacemaker were included. Forty-seven patients with ejection ...

متن کامل

Mechanical dyssynchrony indices from an electrophysiological contact mapping system predict response to CRT

We present a methodology to extract mechanical dyssynchrony indices from an electrophysiological (EP) contact mapping system that was applied to a database of ten patients undergoing Cardiac Resynchronization Therapy (CRT), before and after the therapy. The mechanical dyssynchrony indices were obtained after post-processing high temporal resolution data recorded at several endocardial positions...

متن کامل

Evaluation of global left ventricular function and mechanical dyssynchrony in patients with an asymptomatic left bundle branch block: a real-time 3D echocardiography study.

BACKGROUND A left bundle branch block (LBBB) affects both global left ventricular (LV) function and mechanical dyssynchrony. The aim was to evaluate global LV function and mechanical dyssynchrony with real-time 3D echocardiography (RT3DE), in asymptomatic LBBB patients, healthy volunteers and patients with symptomatic heart failure (HF) and a LBBB. Furthermore, the relation between presence or ...

متن کامل

Comparison of Echocardiographic Markers of Cardiac Dyssynchrony and Latest Left Ventricular Activation Site in Heart Failure Patients with and without Left Bundle Branch Block

BACKGROUND Several echocardiographic markers have been introduced to assess the left ventricular (LV) mechanical dyssynchrony. We studied dyssynchrony markers and the latest LV activation site in heart failure patients with and without left bundle branch block (LBBB). METHODS Conventional echocardiography and tissue velocity imaging were performed for 78 patients (LV ejection fraction ≤ 35%),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 101  شماره 

صفحات  -

تاریخ انتشار 2013