Metallic stents for airway complications after lung transplantation: long-term follow-up.

نویسندگان

  • Nader Abdel-Rahman
  • Mordechai R Kramer
  • Milton Saute
  • Yael Raviv
  • Oren Fruchter
چکیده

OBJECTIVES Bronchial stenosis is still a significant source of morbidity and mortality following lung transplantation (LTX) and often mandating placement of a bronchial stent. It has been suggested that although self-expanding metal stents offer excellent early palliation, their long-term complication rates are unacceptably high, and hence, their usage in many transplantation centres has been nearly abandoned. The aim of the study was to assess short- and long-term complication rates and survival in LTX patients with bronchial stenosis treated with insertion of self-expanding metal stents. METHODS From January 1997 to March 2013, 435 patients underwent LTX (325 single-LTX and 110 bilateral LTX). Of 503 actual anastomoses at risk (derived by subtracting the number of anastomoses in 30 patients who died within 30 days of LTX), 60 airway complications (11.9%) in 47 patients required self-expanding metal stent insertion. We assessed the early results and long-term outcomes and survival compared with LTX patients in whom stents were not required. RESULTS The median follow-up period ranged from 1 to 132 (median 54) months. Immediate relief of symptoms was achieved in the vast majority of patients (95%). One-, three- and five-year survival in patients who required self-expanding metal stent placement were 77.7, 66.6 and 55.5%, respectively. The corresponding survival rates in LTX patients without stents were 69, 64.9 and 61.1% (P > 0.05). CONCLUSIONS Self-expanding metal stents are safe and effective tools in the management of airway complications post-LTX and provide immediate improvement in symptoms and pulmonary function tests in the vast majority of cases. The long-term complication rate is low, and mortality is similar to that in LTX patients who did not require stent insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are metallic stents really safe? A long-term analysis in lung transplant recipients.

Airway complications affect 20% of all lung transplant recipients. Self-expandable metallic stents (SEMS) are one treatment option but their use in benign airway disorders is controversial. We studies the long-term safety of SEMS in lung transplant recipients. Between January 1998 and February 2008, all lung transplant recipients with SEMS were analysed retrospectively at a single centre. Compl...

متن کامل

Airway complications after lung transplantation: long-term outcome of silicone stenting.

BACKGROUND Airway complications remain a significant cause of morbidity after lung transplantation. The majority of the centres that have published their results have used metal stents. OBJECTIVES We report the long-term outcome of silicone stenting and subsequent stent removal in lung transplant recipients with stenotic airway complications. METHOD From 1990 to 2008, 279 patients received ...

متن کامل

The Use of Cook Resonance Metallic Ureteral Stent in Cases of Obstructive Uropathy from Persistent Neoureteral Stenosis, Following Kidney Transplantation

Introduction: Following kidney transplantation, persistent cases of obstructive uropathy from neoureteral stenosis, at the reimplantation site, may require management with permanent, long-term Double-J stenting, following failed open surgical and minimally invasive procedures. We report our experience of the use of Cook Resonance® metallic ureteral stent to manage such cases endourologically. M...

متن کامل

Balloon-expandable Metallic Stents for Airway Diseases.

Stent placement is an essential treatment for airway diseases. Although self-expandable metallic stents and silicone stents are commonly applied for the treatment of airway diseases, these stents are unsuitable for the treatment of small airway diseases encountered in pediatric patients and lung transplant recipients with airway complications. Currently, only vascular balloon-expandable metalli...

متن کامل

Removal of metallic tracheobronchial stents in lung transplantation with flexible bronchoscopy

BACKGROUND Airway complications are among the most challenging problems after lung transplantation, and Self-Expandable Metallic Stents (SEMS) are used to treat airway complications such as stenosis or malacia at the bronchial anastomosis sites. Several transplantation centers are reluctant to use SEMS since their removal is sometimes needed and usually requires the use of rigid bronchoscopy un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 45 5  شماره 

صفحات  -

تاریخ انتشار 2014