The effects of three-piece or single-piece acrylic intraocular lens (IOL) implantation on posterior capsule opacification.
نویسندگان
چکیده
PURPOSE To evaluate the development of posterior capsule opacification (PCO) in patients implanted with 5.5 mm optics, single-piece or three-piece acrylic intraocular lens (IOL) in cataract surgery prospectively. METHODS This study was carried out on 267 eyes of 249 patients implanted with three-piece, 5.5 mm optics, acrylic IOL and 252 eyes of 244 patients implanted with single-piece, 5.5 mm optics, acrylic IOL by phacoemulsification technique between September 2001 and February 2003. A total of 519 eyes of 493 patients were prospectively evaluated for PCO development during the 25-month period. All the patients were analyzed periodically with anterior segment retroillumination photography. The data provided were analyzed with chi-square method. RESULTS The results between the two groups for PCO development were not statistically significant. However, there was a prominent opacification of the posterior capsule where the optic and haptic junction of IOL was positioned in some patients implanted with single-piece IOL. During the follow-up period, no patients implanted with either three-piece or single-piece acrylic IOL required Nd:YAG laser capsulotomy. CONCLUSIONS Biocompatibility and reduced rate of PCO development are among the leading features of new generation IOLs. The intracapsular implantation of 5.5 mm optics acrylic IOLs resulted in decreased incidence of PCO and therefore greater patient satisfaction. Further studies investigating the effects of IOL optics, haptic structure and length, capsulorrhexis size, and IOL material and design features on PCO development will clarify the subject. (Eur J Ophthalmol 2004; 14: #-80).
منابع مشابه
SCIENTIFIC REPORT A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses
Aims: To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). Methods: 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior cap...
متن کاملA prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.
AIMS To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). METHODS 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior cap...
متن کاملSquare-edge intraocular lenses and epithelial lens cell proliferation: implications on posterior capsule opacification in an in vitro model
BACKGROUND To evaluate lens epithelial cell (LEC) proliferation with two different designs (one-piece or three-piece) of hydrophobic acrylic IOLs with 360° square optic edge using an in vitro culture model of posterior capsule opacification (PCO). METHODS This experimental study was conducted at the Department of NEUROFARBA, Section of Pharmacology, University of Florence, Italy. Human LECs w...
متن کاملNd:YAG capsulotomy rates after use of the AcrySof acrylic three piece and one piece intraocular lenses.
BACKGROUND/AIM Acrylic lens size and shape may influence the rate of posterior capsule opacification (PCO) and need for Nd:YAG capsulotomy. The aim of this study is to compare the Nd:YAG capsulotomy rate of the three piece acrylic/PMMA AcrySof MA series lens with the one piece acrylic AcrySof SA series lens. METHODS 434 eyes of 329 patients who had cataract extraction and implantation of one ...
متن کاملAdhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study.
AIMS To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 14 5 شماره
صفحات -
تاریخ انتشار 2004