Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam.

نویسندگان

  • J-E Groetz
  • N Ounoughi
  • C Mavon
  • A Belafrites
  • M Fromm
چکیده

We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have been established. Particular attention was given to the determination of the effective mean energy for the 1.5 keV photons using the PENELOPE code. Other correction factors were determined by means of computer simulation (COMSOL™ and FLUKA). Measurements of air kerma rates under specific operating parameters of the lab-bench X-ray source have been performed at various distances from that source and compared to Monte Carlo calculations. We show that the developed ionization chamber makes it possible to determine accurate photon fluence rates in routine work and will constitute substantial time-savings for future radiobiological experiments based on the use of ultra-soft X-rays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

Air Kerma Calibration Factors and kch Values for PTW Soft X-ray, NACP and Roos Ionization Chambers at Very Low X-ray Energies

Several national and international protocols have been established for the dosimetry of x-ray beams used in radiotherapy. For the very low energy x-rays (0.035 mm1.0 mm Al HVL) only two codes are available: the UK IPEMB Code of Practice and the German standard, DIN 6809 Part 4. The measurement of very low energy x-ray beams is normally performed with parallel plate ionization chambers calibrate...

متن کامل

Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

متن کامل

طراحی و ساخت یک اتاقک یونش با صفحات موازی جهت دزیمتری پرتوهای ایکس تشخیصی

The use of gaseous ionization to calculate the absorbed dose of radiation beams is attractive because of its relative ease, suitable response, high accuracy and also cost-effectiveness. This work introduces the design and fabrication of a new parallel plate ionization chamber with two sensitive volumes. A series of standard tests was performed with x-rays, gamma radiation units, and beta source...

متن کامل

Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 85 8  شماره 

صفحات  -

تاریخ انتشار 2014