Non-invasive removal of sandblasted and acid-etched titanium palatal implants, a retrospective study.

نویسندگان

  • Mirjam Kuhn
  • Peter Göllner
  • Marc Schätzle
  • Michael P Hänggi
چکیده

BACKGROUND Short, rough-surfaced palatal implants are an established and reliable anchor for orthodontic treatment. Until recently, removal was only possible surgically using a hollow cylinder trephine. This standard method retrieves the implant combined with a larger bone volume and is therefore considered invasive and has known complications. Lately, an explantation tool which allows a sufficient force application to break the bone-implant-connection and unscrew the palatal implant was developed and, since its introduction, has been used as the method of choice in several orthodontic offices. OBJECTIVES The aim of this study was to assess the complications caused by removing rough-surfaced palatal implants simply by unscrewing them with an explantation tool in contrast to standard protocol by surgical removal with a trephine. MATERIAL AND METHODS The removal of 73 palatal implants using a customized explantation tool has been evaluated retrospectively and was compared to an existing sample of 44 conventional surgical explantations. RESULTS The new clinical procedure resulted in successful removal of 71 (97.3 per cent) palatal implants. In two cases, the new method failed but removal with the established surgical method was still possible with no further complications. The non-invasive palatal implant removal with a customized explantation tool had less medical complications compared to an existing sample of surgical explantations. CONCLUSIONS User's opinion was that the new method is more easily executed, less invasive, and also applicable without local anaesthesia. Therefore, it is considered to be beneficial for patients and the treatment approach of choice. However, further research is needed for verification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface analysis of machined versus sandblasted and acid-etched titanium implants.

Initially, implant surface analyses were performed on 10 machined implants and on 10 sandblasted and acid-etched implants. Subsequently, sandblasted and acid-etched implant cytotoxicity (using L929 mouse fibroblasts), morphologic differences between cells (osteoblast-like cells MG63) adhering to the machined implant surfaces, and cell anchorage to sandblasted and acid-etched implant surfaces we...

متن کامل

Biomechanical evaluation of a titanium implant surface conditioned by a hydroxide ion solution.

Two groups of titanium dental implants, identical in geometry but different in the treatment of their surfaces, were tested in an in vivo minipig model of the mandible. The surfaces that were tested were, first, sandblasted and acid-etched; and secondly, sandblasted, acid-etched, and conditioned. The removal torque was assessed at 2, 4, and 8 weeks after implantation (n=6 animals in each healin...

متن کامل

Evaluation of Bone Healing on Sandblasted and Acid Etched Implants Coated with Nanocrystalline Hydroxyapatite: An In Vivo Study in Rabbit Femur

This study aimed at investigating if a coating of hydroxyapatite nanocrystals would enhance bone healing over time in trabecular bone. Sandblasted and acid etched titanium implants with and without a submicron thick coat of hydroxyapatite nanocrystals (nano-HA) were implanted in rabbit femur with healing times of 2, 4, and 9 weeks. Removal torque analyses and histological evaluations were perfo...

متن کامل

Osseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.

PURPOSE Zirconia ceramics are a viable alternative to titanium for use as dental implants. However, the smooth surface of zirconia means that longer healing periods are needed to accomplish osseointegration compared to roughened titanium surfaces. Surface modifications can be used to increase the roughness of zirconia. The aim of this study was to assess histologically and compare the degree of...

متن کامل

Scaling of titanium implants entrains inflammation-induced osteolysis

With millions of new dental and orthopedic implants inserted annually, periprosthetic osteolysis becomes a major concern. In dentistry, peri-implantitis management includes cleaning using ultrasonic scaling. We examined whether ultrasonic scaling releases titanium particles and induces inflammation and osteolysis. Titanium discs with machined, sandblasted/acid-etched and sandblasted surfaces we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 2015