A protection system for the JET ITER-like wall based on imaging diagnostics.
نویسندگان
چکیده
The new JET ITER-like wall (made of beryllium and tungsten) is more fragile than the former carbon fiber composite wall and requires active protection to prevent excessive heat loads on the plasma facing components (PFC). Analog CCD cameras operating in the near infrared wavelength are used to measure surface temperature of the PFCs. Region of interest (ROI) analysis is performed in real time and the maximum temperature measured in each ROI is sent to the vessel thermal map. The protection of the ITER-like wall system started in October 2011 and has already successfully led to a safe landing of the plasma when hot spots were observed on the Be main chamber PFCs. Divertor protection is more of a challenge due to dust deposits that often generate false hot spots. In this contribution we describe the camera, data capture and real time processing systems. We discuss the calibration strategy for the temperature measurements with cross validation with thermal IR cameras and bi-color pyrometers. Most importantly, we demonstrate that a protection system based on CCD cameras can work and show examples of hot spot detections that stop the plasma pulse. The limits of such a design and the associated constraints on the operations are also presented.
منابع مشابه
R&D on full tungsten divertor and beryllium wall for JET ITER-like wall project
The ITER reference materials have been tested separately in tokamaks, plasma simulators, ion beams and high heat flux test beds. In order to perform a fully integrated material test JET has launched the ITER-like Wall Project with the aim of installing a full metal wall during the next major shutdown. As a result of R&D projects in 2005–2006, bulk tungsten tiles are foreseen at the outer horizo...
متن کاملDevelopment of a mirror-based endoscope for divertor spectroscopy on JET with the new ITER-like wall (invited).
A new endoscope with optimised divertor view has been developed in order to survey and monitor the emission of specific impurities such as tungsten and the remaining carbon as well as beryllium in the tungsten divertor of JET after the implementation of the ITER-like wall in 2011. The endoscope is a prototype for testing an ITER relevant design concept based on reflective optics only. It may be...
متن کاملSynergy of multiviewing spectroscopic diagnostics on COMPASS-D (invited)
Related Articles Development of multi-channel Doppler spectroscopic measurement system using 8 × 8 multianode photomultiplier tube assembly Rev. Sci. Instrum. 83, 083103 (2012) Electron density and temperature profile diagnostics for C-2 field reversed configuration plasmas Rev. Sci. Instrum. 83, 10E339 (2012) Analysis of edge density fluctuation measured by trial KSTAR beam emission spectrosco...
متن کاملUpgrade of the infrared camera diagnostics for the JET ITER-like wall divertor.
For the new ITER-like wall at JET, two new infrared diagnostics (KL9B, KL3B) have been installed. These diagnostics can operate between 3.5 and 5 μm and up to sampling frequencies of ∼20 kHz. KL9B and KL3B image the horizontal and vertical tiles of the divertor. The divertor tiles are tungsten coated carbon fiber composite except the central tile ...
متن کاملScientific preparation for future D-T campaigns at JET in support of ITER
JET is preparing for deuterium-tritium operation in 2015 with the newly installed ITER-like Wall, neutral beam enhancements (35MW, 20s) and diagnostics upgrades, as part of a phased approach to the full exploitation of JET. Performance projections for stationary ITER scenarios predict Q~0.160.20 for ELMy H-mode plasmas at 4.5MA/3.6T, Q~0.3-0.5 for hybrid plasmas at 3.5MA/3.45T to 4.1MA/4.0T and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 83 10 شماره