Evidence for the Radioactivity of Slow Mesotrons

نویسنده

  • FRANco RAsETTI
چکیده

A beam of mesotrons is selected by means of a fourfold coincidence system of counters, and is allowed to pass through a block of iron 10 cm thick. The absorption of mesotrons by the iron is recorded by means of a battery of anticoincidence counters. It is found that a certain fraction of the stopped mesotrons is associated with the emission of an ionizing particle from the absorber. A special coincidence recording system, whose resolving time is of the order of one microsecond, enables one to establish that the emission of the particles is delayed with respect to the passage of the mesotron by a few microseconds. The delayed particles are interpreted as the electrons resulting from the p-decay of the mesotron. The present experiment establishes only the order of magnitude of the mean life of the mesotron at rest, but more quantitative measurements are in progress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Narrow Cosmic-Ray Showers

It has been found that the cosmic-ray particles which occur in showers of small angular divergence are much more penetrating than those of the usual type of shower. The particles in such "hard showers" are clearly not electrons and are interpreted as medium and low energy mesotrons. The second maximum of the Rossi curve, which is accentuated for small-angle shower arrangements, can be accounted...

متن کامل

Disintegration of Slow Mesotrons

The disintegration of mesotrons at the end of their range was investigated by means of an improved arrangenxent of the type already described by the author. The absorption of a mesotron by a block of aluminum or iron is recorded by a system of coincidence and anticoincidence counters. Another system of counters and circuits registers the delayed emission of a particle, which is interpreted as t...

متن کامل

Variation of the Rate of Decay of Mesotrons with Momentum

In order to determine the dependence of the probability of decay on momentum, mesotrons with range between 196 and 311 g/cm' of lead and mesotrons with range larger than 311 g/cm' of lead were investigated separately. The softer group of mesotrons was found to disintegrate at a rate about three times faster than the more penetrating group, in agreement with the theoretical predictions based on ...

متن کامل

Origin of the Soft Component of Cosmic Rays

HE question as to the origin of the soft component of cosmic rays in the atmosphere has been the subject of much discussion in the last years. ' ' Until recently the general belief was that the soft component is produced partly by incoming primary electrons, partly by electrons arising from the decay of mesotrons and from collision processes of mesotrons in air. Lately Schein, Jesse, and Wollan...

متن کامل

The Slow, Lingering Death of the English NHS; Comment on “Who Killed the English National Health Service?”

The death of the English National Health Service (NHS) may be slow in coming but that does not mean that it is not the Conservative-led UK government’s desired end state. The government is displaying tactical cunning in achieving its long-term purpose to remould the British state. Powell seeks greater clarity amidst the confusion but the lack of clarity is a principal weapon in the government’s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011