A New Method for Calculating Femoral Anterior Cortex Point Location and Its Effect on Component Sizing and Placement

نویسندگان

  • Mohamed R. Mahfouz
  • Emam ElHak Abdel Fatah
  • Lyndsay Bowers
  • Giles Scuderi
چکیده

BACKGROUND Variation in anterior femoral cortex morphology can cause improper component placement and alignment. When surgical inaccuracies occur, the mechanical properties of the distal femur may be altered, which could result in lower surgical success rates and an increased chance of postoperative complications. QUESTIONS/PURPOSES The purpose of the study is to come up with a reproducible computational algorithm to simulate what the surgeon does in the operating room. This method could help in surgical preplanning, patient-specific instruments, and implant design. From there, we evaluated (1) the angular difference between reference alignment axes; and (2) whether the location of the anterior cortex point and alignment axes had an effect on implant placement and amount of bone resected in seven implant systems. METHODS We analyzed 470 femurs from white and black individuals. Two points were defined using automatic three-dimensional landmarking: sizing point and femoral resection anterior cortex (FRAC) point. Alignment axes including the transepicondylar, posterior condylar, distal anatomical (DAA), and mechanical axes (MAs) were automatically calculated and used along with the resection point to define the anterior reference plane. Two mechanical axes were defined for the purpose of this study: MA-1 is a virtual construct used in navigated surgeries defined as the axis joining the center of the femoral head and the knee center and MA-2 was calculated as the axis joining the center of the femoral head and distal exit point of the DAA. Amounts of anterior, posterior, and distal resected bone were calculated along with the difference in orientation between the alignment axes. RESULTS The mean angular difference between transepicondylar axis and posterior condylar axis (PCA) was 5.44°±2.99°. All seven implant families showed more total bone resection on both the lateral and medial sides when the implants were aligned using MA-2 and PCA+3 of external rotation (PCA+3) when compared with using MA-1 and PCA+3 (p<0.01). Using MA-2 and PCA+3 as an alignment method reduced the amount of bone resection on both medial and lateral anterior surfaces from 1 to 2 mm. CONCLUSION The FRAC point is a key landmark in the placement and sizing of the femoral component. Improper sizing, notching, undercutting, or overstuffing can occur based on selecting the highest or lowest cortex point. CLINICAL RELEVANCE Balanced placement, prevention of notching, and anterior and posterior cut balancing were accomplished when using the suggested cortex point.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using the Modified Shuffled Frog Leaping Algorithm for Optimal Sizing and location of Distributed Generation Resources for Reliability Improvement

Restructuring the recent developments in the power system and problems arising from construction as well as the maintenance of large power plants lead to increase in using the Distributed Generation (DG) resources. DG units due to its specifications, technology and location network connectivity can improve system and load point reliability indices. In this paper, the allocation and sizing of di...

متن کامل

Optimal Placement and Sizing of Fault Current Limiter in a Real Network: a Case Study (TECHNICAL NOTE)

In this paper, the effect of number and fault current limiter(FCL) location has been investigated in order to have maximum reduction of short circuit current level in all buses in a real network. To do so, the faulty buses were identified in terms of short circuit current level by computing short circuits on the desired network. Then, while the fault current limit was modeled, its optimal locat...

متن کامل

Optimal Placement and Sizing of Distributed Generation Via an Improved Nondominated Sorting Genetic Algorithm II

The use of distributed generation units in distribution networks has attracted the attention of network managers due to its great benefits. In this research, the location and determination of the capacity of distributed generation (DG) units for different purposes has been studied simultaneously. The multi-objective functions in the optimization model are reducing system line losses; reducing v...

متن کامل

Optimal Placement and Sizing of TCSC & SVC for Improvement Power System Operation using Crow Search Algorithm

Abstract: The need for more efficient power systems has prompted the use of a new technologies includes Flexible AC transmission system (FACTS) devices. FACTS devices provides new opportunity for controlling the line power flow and minimizing losses while maintaining the bus voltages within a permissible limit. In this thesis a new method is proposed for optimal placement and sizing of Thyristo...

متن کامل

Optimal placement and sizing of distributed generation considering FACTS devices and load uncertainty using hybrid sine-cosine algorithm and particle swarm optimization (HSCA-PSO)

Using Distributed Generation (DG) in electrical distribution networks brings many advantages and thus, optimal placement and sizing of these units become important. Most of the researches in this field neglect the effect of transmission system on distribution section. These researches also ignore the effect of Flexible Alternating Current Transmission Systems (FACTS). This thesis proposes a new...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 473  شماره 

صفحات  -

تاریخ انتشار 2015